{ "currentVersion": 11.3, "cimVersion": "3.3.0", "id": 110007, "name": "Medium Voltage Attachment", "type": "Feature Layer", "parentLayer": { "id": 105023, "name": "Electric Junction" }, "defaultVisibility": false, "minScale": 501, "maxScale": 0, "canScaleSymbols": false, "geometryType": "esriGeometryPoint", "description": "", "copyrightText": "", "editFieldsInfo": { "creationDateField": "CREATIONDATE", "creatorField": "CREATOR", "editDateField": "LASTUPDATE", "editorField": "UPDATEDBY" }, "ownershipBasedAccessControlForFeatures": null, "syncCanReturnChanges": true, "relationships": [], "isDataVersioned": true, "isDataArchived": false, "infoInEstimates": [ "extent" ], "isDataBranchVersioned": false, "isDataReplicaTracked": false, "isCoGoEnabled": false, "supportsRollbackOnFailureParameter": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "supportsValidateSQL": true, "supportsCoordinatesQuantization": true, "supportsQuantizationEditMode": true, "supportsCalculate": true, "supportsASyncCalculate": true, "supportsDatumTransformation": true, "advancedQueryCapabilities": { "supportsPagination": true, "supportsTrueCurve": true, "supportsQueryWithDistance": true, "supportsReturningQueryExtent": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsAdvancedQueryRelated": true, "supportsQueryRelatedPagination": true, "supportsCurrentUserQueries": true, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryWithResultType": true, "supportsReturningGeometryCentroid": false, "supportsSqlExpression": true, "supportsQueryWithDatumTransformation": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsQueryAnalytic": true }, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": true, "supportsPercentileAnalytic": true }, "advancedEditingCapabilities": { "supportedSqlFormatsInCalculate": [ "standard" ], "supportsAsyncApplyEdits": true, "supportsApplyEditsbyUploadID": true, "supportedApplyEditsUploadIDFormats": "JSON" }, "hasMetadata": true, "extent": { "xmin": 6478410.546913639, "ymin": 1794445.4028973132, "xmax": 6484073.1448403895, "ymax": 1804095.5269697309, "spatialReference": { "wkid": 103004, "latestWkid": 6418, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -115211800, "falseY": -93821500, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "sourceSpatialReference": { "wkid": 103004, "latestWkid": 6418, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -115211800, "falseY": -93821500, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "assettype", "defaultSymbol": { "type": "esriPMS", "url": "e81273a688131c8e59a15552b1adf484", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAA4AAAAOCAYAAAAfSC3RAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAA+klEQVQokaWRMQqDQBBFp9gDiLa5hIWNhQcIBIscIZ1FsMgBtna3lK1cCARiFbCKYJUr7A0sbAOC2IdJsmGN2RTJL4d5zJ//Cfwo8j4Iw3A9juPSnCmlDgBwsYK+72+CIKBpmi7MuRAiZoztAGA/AxGKoohSSheO40xcZFnmAQBnjIGGibaHlz5BH+AeAKo7iD+hPRuklSSJ1zTNSin1AH8R+Rvse7T+Xb2xQ3RPeZ7HnHPP9mfbtlDX9XUYhpN58SKlxJ54URSY3gwqy/IqhNh2XXeeWMV+pJTgui7H9Ex7eOkJHWc/ahh7wsjNIdrTl2wgqsKeLPm8dAPXynTfTMaXIQAAAABJRU5ErkJggg==", "contentType": "image/png", "width": 10, "height": 10, "angle": 0, "xoffset": 0, "yoffset": 0 }, "defaultLabel": "Other", "uniqueValueGroups": [ { "heading": "Asset Type", "classes": [ { "label": "Unknown", "description": "Unknown", "symbol": { "type": "esriPMS", "url": "983478649a1c9860eadc7204431965e6", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "0" ] ] }, { "label": "Overhead", "description": "Overhead", "symbol": { "type": "esriPMS", "url": "acb00d7ece8b0a8648415a84023c0fc8", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "60" ] ] }, { "label": "Underground", "description": "Underground", "symbol": { "type": "esriPMS", "url": "af3eebeee222f2e47a738155b29c73f4", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "61" ] ] }, { "label": "Riser", "description": "Riser", "symbol": { "type": "esriPMS", "url": "e11b80f0132ddc70f77ec3d8cbb01c1e", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "values": [ [ "62" ] ] } ] } ], "uniqueValueInfos": [ { "symbol": { "type": "esriPMS", "url": "983478649a1c9860eadc7204431965e6", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "0", "label": "Unknown" }, { "symbol": { "type": "esriPMS", "url": "acb00d7ece8b0a8648415a84023c0fc8", "imageData": "iVBORw0KGgoAAAANSUhEUgAAABIAAAASCAYAAABWzo5XAAAACXBIWXMAAA7EAAAOxAGVKw4bAAABuUlEQVQ4jb2Uv0sCYRzGHz09IxORC64fEBEkOTQELkotRZvLBUFTtElQ/4B/gBDRlA1tDW0WDkJTm2RLW0PU1BBOHg6XRhdpPPKevKenNETf8b3v9+P3fZ7nNYA/qsB/gGYATAMIAVAB2AAsADUA5m9AEQDzALS+c1WcaQL4KOCeIEKWOTS+fRAfW1lPK/pcyheOxPFlm99m7d66PL6wH27ZmwZQdWD9IG6iRvePUrObRn5LV7Aa8yMR9qNuh7RKYzGTnzrLvF+fZlvFwguApIC5QNRE4yaE5BaCWIv5ex8nVR8MXcHShA+7ODwH4MA4V5NBFBa8DjeRIXJxOwKvNnb2WsVCTsy5QHQH1ITXGVWGrqD0Fo1LurquRldAYfmroyrB70HV5aoMovoq3aGw1GRY1e0O2CfNuUDMhkaL6Q7XH1aVRhvsk+ZcICZWY05oMd3xuuJTs438c9P8uCuXxZHZD+KBxbAxJ7SYWxm6InLU6W5CyGf15kRY7zyZgUAy9mnRlKXFJbpDYUWyuYkEefUS2xGOSU2yWeTEqxxI7/F6PVoH5rz+bk6k18/h7nXkGvU3wuaBgWH1AznyqlvOcF4eAAAAAElFTkSuQmCC", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "60", "label": "Overhead" }, { "symbol": { "type": "esriPMS", "url": "af3eebeee222f2e47a738155b29c73f4", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "61", "label": "Underground" }, { "symbol": { "type": "esriPMS", "url": "e11b80f0132ddc70f77ec3d8cbb01c1e", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "62", "label": "Riser" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 215, 252, 251, 255 ], "toColor": [ 215, 252, 251, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 238, 182, 252, 255 ], "toColor": [ 238, 182, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 197, 184, 255 ], "toColor": [ 252, 197, 184, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 182, 252, 179, 255 ], "toColor": [ 182, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 252, 197, 255 ], "toColor": [ 252, 252, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 205, 252, 255 ], "toColor": [ 179, 205, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 187, 214, 255 ], "toColor": [ 252, 187, 214, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 204, 252, 214, 255 ], "toColor": [ 204, 252, 214, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 237, 207, 252, 255 ], "toColor": [ 237, 207, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 194, 179, 252, 255 ], "toColor": [ 194, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 215, 223, 255 ], "toColor": [ 252, 215, 223, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 207, 229, 252, 255 ], "toColor": [ 207, 229, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 226, 189, 255 ], "toColor": [ 252, 226, 189, 255 ] } ] } }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.symbolrotation", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "hasM": true, "hasZ": true, "enableZDefaults": false, "supportsVCSProjection": true, "allowUpdateWithoutMValues": false, "allowGeometryUpdates": true, "allowTrueCurvesUpdates": true, "onlyAllowTrueCurveUpdatesByTrueCurveClients": true, "hasAttachments": true, "supportsAttachmentsByUploadId": true, "supportsAttachmentsResizing": true, "supportsApplyEditsWithGlobalIds": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "objectIdField": "OBJECTID", "globalIdField": "GlobalID_1", "displayField": "subnetworkname", "typeIdField": "assettype", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null, "editable": false, "nullable": false, "defaultValue": null, "modelName": "OBJECTID" }, { "name": "assetgroup", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null, "editable": true, "nullable": false, "defaultValue": 0, "modelName": "assetgroup", "required": true }, { "name": "assettype", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null, "editable": true, "nullable": false, "defaultValue": 0, "modelName": "assettype", "required": true }, { "name": "associationstatus", "type": "esriFieldTypeSmallInteger", "alias": "Association status", "domain": { "type": "codedValue", "name": "Network_5_AssociationStatus", "description": "Indicates how the feature participates in associations.", "codedValues": [ { "name": "None", "code": 0 }, { "name": "Container", "code": 1 }, { "name": "Structure", "code": 2 }, { "name": "Content", "code": 4 }, { "name": "Content and Container", "code": 5 }, { "name": "Content and Structure", "code": 6 }, { "name": "Attachment", "code": 8 }, { "name": "Attachment and Container", "code": 9 }, { "name": "Attachment and Structure", "code": 10 }, { "name": "Attachment and Content", "code": 12 }, { "name": "Attachment and Content and Container", "code": 13 }, { "name": "Attachment and Content and Structure", "code": 14 }, { "name": "Visible Content", "code": 16 }, { "name": "Visible Content and Container", "code": 17 }, { "name": "Visible Content and Structure", "code": 18 }, { "name": "Visible Content and Attachment", "code": 24 }, { "name": "Visible Content and Attachment and Container", "code": 25 }, { "name": "Visible Content and Attachment and Structure", "code": 26 }, { "name": "Connectivity", "code": 32 }, { "name": "Connectivity and Container", "code": 33 }, { "name": "Connectivity and Structure", "code": 34 }, { "name": "Connectivity and Content", "code": 36 }, { "name": "Connectivity and Content and Container", "code": 37 }, { "name": "Connectivity and Content and Structure", "code": 38 }, { "name": "Connectivity and Attachment", "code": 40 }, { "name": "Connectivity and Attachment and Container", "code": 41 }, { "name": "Connectivity and Attachment and Structure", "code": 42 }, { "name": "Connectivity and Attachment and Content", "code": 44 }, { "name": "Connectivity and Attachment and Content and Container", "code": 45 }, { "name": "Connectivity and Attachment and Content and Structure", "code": 46 }, { "name": "Connectivity and Visible Content", "code": 48 }, { "name": "Connectivity and Visible Content and Container", "code": 49 }, { "name": "Connectivity and Visible Content and Structure", "code": 50 }, { "name": "Connectivity and Visible Content and Attachment", "code": 56 }, { "name": "Connectivity and Visible Content and Attachment and Container", "code": 57 }, { "name": "Connectivity and Visible Content and Attachment and Structure", "code": 58 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": false, "nullable": false, "defaultValue": 0, "modelName": "associationstatus" }, { "name": "isconnected", "type": "esriFieldTypeSmallInteger", "alias": "Is connected", "domain": { "type": "codedValue", "name": "Network_5_IsConnected", "description": "Indicates if the feature is connected to a subnetwork controller.", "codedValues": [ { "name": "False", "code": 0 }, { "name": "True", "code": 1 }, { "name": "Unknown", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": false, "nullable": false, "defaultValue": 2, "modelName": "isconnected" }, { "name": "creationdate", "type": "esriFieldTypeDate", "alias": "Creation date", "domain": null, "editable": false, "nullable": true, "length": 8, "defaultValue": null, "modelName": "creationdate" }, { "name": "creator", "type": "esriFieldTypeString", "alias": "Creator", "domain": null, "editable": false, "nullable": true, "length": 255, "defaultValue": null, "modelName": "creator" }, { "name": "lastupdate", "type": "esriFieldTypeDate", "alias": "Last update", "domain": null, "editable": false, "nullable": true, "length": 8, "defaultValue": null, "modelName": "lastupdate" }, { "name": "updatedby", "type": "esriFieldTypeString", "alias": "Updated by", "domain": null, "editable": false, "nullable": true, "length": 255, "defaultValue": null, "modelName": "updatedby" }, { "name": "globalid", "type": "esriFieldTypeGUID", "alias": "Global ID", "domain": null, "editable": false, "nullable": false, "length": 38, "defaultValue": "{00000000-0000-0000-0000-000000000000}", "modelName": "globalid" }, { "name": "assetid", "type": "esriFieldTypeString", "alias": "Asset ID", "domain": null, "editable": true, "nullable": true, "length": 64, "defaultValue": null, "modelName": "assetid" }, { "name": "nominalvoltage", "type": "esriFieldTypeInteger", "alias": "Nominal Voltage (L-L)", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LL", "description": "Combined Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "253 V", "code": 253 }, { "name": "480 V", "code": 480 }, { "name": "528 V", "code": 528 }, { "name": "600 V", "code": 600 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "nominalvoltage" }, { "name": "maxvoltage", "type": "esriFieldTypeInteger", "alias": "Maximum Operating Voltage (L-L)", "domain": { "type": "codedValue", "name": "Electric_Combined_Maximum_Voltage", "description": "Combined Maximum Voltage Values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1.1 mV", "code": 1100000 }, { "name": "1.2 mV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "maxvoltage" }, { "name": "nominalvoltagelg", "type": "esriFieldTypeInteger", "alias": "Nominal Voltage (L-G)", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LG", "description": "Combined Line to Ground Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "nominalvoltagelg" }, { "name": "phasesnormal", "type": "esriFieldTypeSmallInteger", "alias": "Phases Normal", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasesnormal" }, { "name": "phasescurrent", "type": "esriFieldTypeSmallInteger", "alias": "User Assigned Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasescurrent" }, { "name": "phasessummer", "type": "esriFieldTypeSmallInteger", "alias": "Summer Configuration Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasessummer" }, { "name": "phaseswinter", "type": "esriFieldTypeSmallInteger", "alias": "Winter Configuration Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phaseswinter" }, { "name": "phasesplan", "type": "esriFieldTypeSmallInteger", "alias": "Planned Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasesplan" }, { "name": "phasesenergized", "type": "esriFieldTypeSmallInteger", "alias": "Phases Energized", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 0, "modelName": "phasesenergized" }, { "name": "phasessubstituted", "type": "esriFieldTypeInteger", "alias": "Phases Substituted", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasessubstituted" }, { "name": "phasefrequency", "type": "esriFieldTypeSmallInteger", "alias": "Phase Frequency", "domain": { "type": "codedValue", "name": "Electric_System_Frequency", "description": "Valid Frequencies for Phase", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 hz", "code": 50 }, { "name": "60 hz", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasefrequency" }, { "name": "numphasesconstructed", "type": "esriFieldTypeSmallInteger", "alias": "Num Phases Built", "domain": { "type": "codedValue", "name": "Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "numphasesconstructed" }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "Lifecycle_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Proposed and Approved", "code": 3 }, { "name": "Under Construction", "code": 4 }, { "name": "Approved and Under Construction", "code": 6 }, { "name": "Proposed, Approved and Under Construction", "code": 7 }, { "name": "In Service", "code": 8 }, { "name": "In Service and Under Construction", "code": 12 }, { "name": "In Service, Under Construction, and Approved", "code": 14 }, { "name": "In Service, Under Construction, Approved and Proposed", "code": 15 }, { "name": "To Be Retired", "code": 16 }, { "name": "In Service and To Be Retired", "code": 24 }, { "name": "Abandoned", "code": 32 }, { "name": "In Service, Proposed, and Abandoned", "code": 41 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": false, "defaultValue": 8, "modelName": "lifecyclestatus" }, { "name": "installdate", "type": "esriFieldTypeDate", "alias": "Install Date", "domain": null, "editable": true, "nullable": true, "length": 8, "defaultValue": null, "modelName": "installdate" }, { "name": "retireddate", "type": "esriFieldTypeDate", "alias": "Retired Date", "domain": null, "editable": true, "nullable": true, "length": 8, "defaultValue": null, "modelName": "retireddate" }, { "name": "inservicedate", "type": "esriFieldTypeDate", "alias": "In-Service Date", "domain": null, "editable": true, "nullable": true, "length": 8, "defaultValue": null, "modelName": "inservicedate" }, { "name": "manufacturer", "type": "esriFieldTypeSmallInteger", "alias": "Equipment Maker", "domain": { "type": "codedValue", "name": "Electric_Equipment_Manufacturer", "description": "All Electric Equipment Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "American Electric Lighting", "code": 2 }, { "name": "Beckwith Electric Company", "code": 3 }, { "name": "Canada Power Products", "code": 4 }, { "name": "Carte International", "code": 5 }, { "name": "Central Moloney Inc", "code": 6 }, { "name": "Challenger Electrical Equip CO", "code": 7 }, { "name": "Chardon Group", "code": 8 }, { "name": "Cooper Industries/Eaton", "code": 9 }, { "name": "Dowzer/Hevi Duty", "code": 10 }, { "name": "ERICO", "code": 11 }, { "name": "ERM Co", "code": 12 }, { "name": "ESCO Transformer Co", "code": 13 }, { "name": "Fargo Electric", "code": 14 }, { "name": "Farranti-Packard Transformer", "code": 15 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Glavan Electric", "code": 18 }, { "name": "Gordon Electric", "code": 19 }, { "name": "Gould Shawmut", "code": 20 }, { "name": "Howard Industries", "code": 21 }, { "name": "Hubbell", "code": 22 }, { "name": "Inertia Engineering & Machine Works", "code": 23 }, { "name": "ITT Bell and Gossett", "code": 24 }, { "name": "Jimelco", "code": 25 }, { "name": "Johnson Electric", "code": 26 }, { "name": "Kaiser", "code": 27 }, { "name": "Lindsey USA", "code": 28 }, { "name": "LittelFuse", "code": 29 }, { "name": "Magnetic Electric Co", "code": 30 }, { "name": "Meramac", "code": 31 }, { "name": "Mersen", "code": 32 }, { "name": "MGM Transformer Company", "code": 33 }, { "name": "Mid Central Electric", "code": 34 }, { "name": "Nova", "code": 35 }, { "name": "Pacific Air Switch Corp", "code": 36 }, { "name": "Pauwels", "code": 37 }, { "name": "Pennsylvania Transformer CO", "code": 38 }, { "name": "Philips", "code": 39 }, { "name": "Pole Star", "code": 40 }, { "name": "Power Delivery Products", "code": 41 }, { "name": "Power Partners", "code": 42 }, { "name": "Preformed Line Products", "code": 43 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "Sangamo", "code": 46 }, { "name": "Schneider Electric", "code": 47 }, { "name": "Schwager Wood", "code": 48 }, { "name": "Schweitzer", "code": 49 }, { "name": "Siemens", "code": 50 }, { "name": "Shallbetter", "code": 51 }, { "name": "Sola Hevi-Duty", "code": 52 }, { "name": "Sylvania", "code": 53 }, { "name": "T&R Electric", "code": 54 }, { "name": "TYCO", "code": 55 }, { "name": "Uptegraff", "code": 56 }, { "name": "Van Tran Transformers", "code": 57 }, { "name": "Other", "code": 9999 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "manufacturer" }, { "name": "spatialsource", "type": "esriFieldTypeSmallInteger", "alias": "Spatial Source", "domain": { "type": "codedValue", "name": "Spatial_Source", "description": "Source of the spatial location", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "As-Built", "code": 1 }, { "name": "CAD", "code": 2 }, { "name": "Digitized", "code": 3 }, { "name": "GPS/GNSS", "code": 4 }, { "name": "Field Sketch", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "spatialsource" }, { "name": "spatialconfidence", "type": "esriFieldTypeSmallInteger", "alias": "Spatial Confidence", "domain": { "type": "codedValue", "name": "Spatial_Confidence", "description": "Confidence in the accuracy of the spatial data", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High", "code": 1 }, { "name": "Medium", "code": 2 }, { "name": "Low", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "spatialconfidence" }, { "name": "grounding", "type": "esriFieldTypeSmallInteger", "alias": "System Grounding", "domain": { "type": "codedValue", "name": "Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "grounding" }, { "name": "notes", "type": "esriFieldTypeString", "alias": "General Notes", "domain": null, "editable": true, "nullable": true, "length": 2000, "defaultValue": null, "modelName": "notes" }, { "name": "symbolrotation", "type": "esriFieldTypeSmallInteger", "alias": "Symbol Rotation", "domain": { "type": "range", "name": "Symbol_Rotation", "description": "Valid range of degrees for rotation", "range": [ 0, 359 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "symbolrotation" }, { "name": "maintby", "type": "esriFieldTypeSmallInteger", "alias": "Maintained By", "domain": { "type": "codedValue", "name": "Asset_Manager", "description": "The manager of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 1, "modelName": "maintby" }, { "name": "ownedby", "type": "esriFieldTypeSmallInteger", "alias": "Owned by", "domain": { "type": "codedValue", "name": "Asset_Owner", "description": "The owner of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 1, "modelName": "ownedby" }, { "name": "subnetworkname", "type": "esriFieldTypeString", "alias": "Subnetwork name", "domain": null, "editable": false, "nullable": false, "length": 2000, "defaultValue": "Unknown", "modelName": "subnetworkname" }, { "name": "supportedsubnetworkname", "type": "esriFieldTypeString", "alias": "Supported subnetwork name", "domain": null, "editable": false, "nullable": false, "length": 2000, "defaultValue": "Unknown", "modelName": "supportedsubnetworkname" }, { "name": "supportingsubnetworkname", "type": "esriFieldTypeString", "alias": "Supporting subnetwork name", "domain": null, "editable": false, "nullable": false, "length": 2000, "defaultValue": "Unknown", "modelName": "supportingsubnetworkname" }, { "name": "validationstatus", "type": "esriFieldTypeSmallInteger", "alias": "Validation status", "domain": { "type": "codedValue", "name": "Validation Status", "description": "The current record's validation status.", "codedValues": [ { "name": "No calculation required, no validation required, no error", "code": 0 }, { "name": "No calculation required, no validation required, has error(s)", "code": 1 }, { "name": "No calculation required, validation required, no error", "code": 2 }, { "name": "No calculation required, validation required, has error(s)", "code": 3 }, { "name": "Calculation required, no validation required, no error", "code": 4 }, { "name": "Calculation required, no validation required, has error(s)", "code": 5 }, { "name": "Calculation required, validation required, no error", "code": 6 }, { "name": "Calculation required, validation required, has error(s)", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "editable": false, "nullable": true, "defaultValue": 6, "modelName": "validationstatus" }, { "name": "GlobalID_1", "type": "esriFieldTypeGlobalID", "alias": "GlobalID_1", "domain": null, "editable": false, "nullable": false, "length": 38, "defaultValue": null, "modelName": "GlobalID_1" }, { "name": "FACILITYID", "type": "esriFieldTypeString", "alias": "FacilityID", "domain": null, "editable": true, "nullable": true, "length": 255, "defaultValue": null, "modelName": "FACILITYID" }, { "name": "GRIDID", "type": "esriFieldTypeString", "alias": "GridID", "domain": null, "editable": true, "nullable": true, "length": 5, "defaultValue": null, "modelName": "GRIDID" }, { "name": "IDNumber", "type": "esriFieldTypeString", "alias": "ID Number", "domain": null, "editable": true, "nullable": true, "length": 5, "defaultValue": null, "modelName": "IDNumber" } ], "geometryField": { "name": "shape", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null, "editable": true, "nullable": false, "defaultValue": null, "modelName": "shape" }, "indexes": [ { "name": "I512globalid", "fields": "globalid", "isAscending": true, "isUnique": false, "description": "" }, { "name": "UUID_85", "fields": "GlobalID_1", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S10_idx", "fields": "shape", "isAscending": true, "isUnique": true, "description": "" } ], "datesInUnknownTimezone": false, "dateFieldsTimeReference": { "timeZone": "UTC", "respectsDaylightSaving": false }, "preferredTimeReference": null, "types": [ { "id": 0, "name": "Unknown", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} }, "templates": [ { "name": "Unknown", "description": "", "prototype": { "attributes": { "assetgroup": 7, "GRIDID": null, "ownedby": 1, "phasesplan": null, "numphasesconstructed": 3, "manufacturer": null, "spatialsource": 0, "notes": null, "symbolrotation": 0, "assettype": 0, "FACILITYID": null, "installdate": null, "lifecyclestatus": 8, "maintby": 1, "phasefrequency": null, "IDNumber": null, "phasessubstituted": null, "grounding": null, "spatialconfidence": 0, "inservicedate": null, "retireddate": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesenergized": 0 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 60, "name": "Overhead", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} }, "templates": [ { "name": "Overhead", "description": "", "prototype": { "attributes": { "assetgroup": 7, "GRIDID": null, "ownedby": 1, "phasesplan": null, "numphasesconstructed": 3, "manufacturer": null, "spatialsource": 0, "notes": null, "symbolrotation": 0, "assettype": 60, "FACILITYID": null, "installdate": null, "lifecyclestatus": 8, "maintby": 1, "phasefrequency": null, "IDNumber": null, "phasessubstituted": null, "grounding": null, "spatialconfidence": 0, "inservicedate": null, "retireddate": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesenergized": 0 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 61, "name": "Underground", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} }, "templates": [ { "name": "Underground", "description": "", "prototype": { "attributes": { "assetgroup": 7, "GRIDID": null, "ownedby": 1, "phasesplan": null, "numphasesconstructed": 3, "manufacturer": null, "spatialsource": 0, "notes": null, "symbolrotation": 0, "assettype": 61, "FACILITYID": null, "installdate": null, "lifecyclestatus": 8, "maintby": 1, "phasefrequency": null, "IDNumber": null, "phasessubstituted": null, "grounding": null, "spatialconfidence": 0, "inservicedate": null, "retireddate": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesenergized": 0 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 62, "name": "Riser", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} }, "templates": [ { "name": "Riser", "description": "", "prototype": { "attributes": { "assetgroup": 7, "GRIDID": null, "assettype": 62, "FACILITYID": null, "ownedby": 1, "manufacturer": null, "inservicedate": null, "phasesplan": null, "numphasesconstructed": 3, "symbolrotation": null, "maintby": 1, "retireddate": null, "IDNumber": null, "installdate": null, "notes": null, "grounding": null, "spatialconfidence": null, "spatialsource": null, "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "lifecyclestatus": 8 } }, "drawingTool": "esriFeatureEditToolPoint" } ] } ], "templates": [], "subtypes": [ { "code": 0, "name": "Unknown", "defaultValues": { "assetgroup": 0, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": null, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Network_5_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 1, "name": "High Voltage Attachment", "defaultValues": { "assetgroup": 1, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Attachment", "description": "High Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "DC Overhead", "code": 3 }, { "name": "DC Underground", "code": 4 }, { "name": "AC Riser", "code": 5 }, { "name": "DC Riser", "code": 6 }, { "name": "AC Submersible", "code": 7 }, { "name": "DC Submersible", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 2, "name": "High Voltage Connection Point", "defaultValues": { "assetgroup": 2, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Connection_Point", "description": "High Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Splice", "code": 20 }, { "name": "AC Tap", "code": 21 }, { "name": "DC Overhead Splice", "code": 22 }, { "name": "DC Tap", "code": 23 }, { "name": "AC Busbar Tap", "code": 24 }, { "name": "DC Busbar Tap", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 3, "name": "High Voltage Line End", "defaultValues": { "assetgroup": 3, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_High_Voltage_Line_End", "description": "High Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 41 }, { "name": "DC Overhead", "code": 42 }, { "name": "AC Busbar Terminator", "code": 45 }, { "name": "DC Busbar Terminator", "code": 46 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 7, "name": "Medium Voltage Attachment", "defaultValues": { "assetgroup": 7, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Attachment", "description": "Medium Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead", "code": 60 }, { "name": "Underground", "code": 61 }, { "name": "Riser", "code": 62 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 8, "name": "Medium Voltage Connection Point", "defaultValues": { "assetgroup": 8, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Connection_Point", "description": "Medium Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Busbar Tap", "code": 80 }, { "name": "Overhead Splice", "code": 81 }, { "name": "Overhead Tap", "code": 82 }, { "name": "Underground Solid Connection", "code": 83 }, { "name": "Underground Splice", "code": 84 }, { "name": "Neutral Connection", "code": 85 }, { "name": "Overhead Solid Connection", "code": 86 }, { "name": "Underground Phase Connector", "code": 87 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 9, "name": "Medium Voltage Line End", "defaultValues": { "assetgroup": 9, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Medium_Voltage_Line_End", "description": "Medium Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Busbar Terminator", "code": 160 }, { "name": "Overhead Line End", "code": 161 }, { "name": "Underground Terminator", "code": 162 }, { "name": "Overhead Wire Change", "code": 163 }, { "name": "Underground Wire Change", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 4, "name": "Low Voltage Attachment", "defaultValues": { "assetgroup": 4, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Attachment", "description": "Low Voltage Attachment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 101 }, { "name": "AC Underground", "code": 102 }, { "name": "DC Overhead", "code": 103 }, { "name": "DC Underground", "code": 104 }, { "name": "AC Riser", "code": 105 }, { "name": "DC Riser", "code": 106 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 5, "name": "Low Voltage Connection Point", "defaultValues": { "assetgroup": 5, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Connection_Point", "description": "Low Voltage Connection Point", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Splice", "code": 120 }, { "name": "DC Overhead Splice", "code": 121 }, { "name": "AC Busbar Tap", "code": 124 }, { "name": "DC Busbar Tap", "code": 125 }, { "name": "AC Underground Splice", "code": 126 }, { "name": "DC Underground Splice", "code": 127 }, { "name": "AC Overhead Tap", "code": 128 }, { "name": "DC Overhead Tap", "code": 129 }, { "name": "AC Underground Solid Connection", "code": 130 }, { "name": "DC Underground Solid Connection", "code": 131 }, { "name": "AC Overhead Solid Connection", "code": 132 }, { "name": "DC Overhead Solid Connection", "code": 133 }, { "name": "AC Underground Phase Connector", "code": 134 }, { "name": "DC Underground Phase Connector", "code": 135 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 6, "name": "Low Voltage Line End", "defaultValues": { "assetgroup": 6, "assettype": 0, "associationstatus": 0, "isconnected": 2, "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "nominalvoltage": null, "maxvoltage": null, "nominalvoltagelg": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "lifecyclestatus": 8, "installdate": null, "retireddate": null, "inservicedate": null, "manufacturer": null, "spatialsource": null, "spatialconfidence": null, "grounding": null, "notes": null, "symbolrotation": null, "maintby": 1, "ownedby": 1, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Junction_Low_Voltage_Line_End", "description": "Low Voltage Line End", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Line End", "code": 141 }, { "name": "DC Overhead Line End", "code": 142 }, { "name": "AC Underground Terminator", "code": 143 }, { "name": "DC Underground Terminator", "code": 144 }, { "name": "AC Overhead Wire Change", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "grounding": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } } ], "maxRecordCount": 500, "supportedQueryFormats": "JSON, geoJSON, PBF", "supportedExportFormats": "sqlite,filegdb,shapefile,csv,geojson", "capabilities": "Query,Create,Update,Delete,Uploads,Editing,Sync", "useStandardizedQueries": true, "bigIntegerRestrictedTo53Bits": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "attachmentProperties": [ { "name": "id", "fieldName": "attachmentid", "isEnabled": true }, { "name": "globalId", "fieldName": "GLOBALID", "isEnabled": false }, { "name": "name", "fieldName": "att_name", "isEnabled": true }, { "name": "size", "fieldName": "data_size", "isEnabled": true }, { "name": "contentType", "fieldName": "content_type", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "attachmentid", "type": "esriFieldTypeOID", "alias": "attachmentid", "domain": null, "editable": false, "nullable": false, "defaultValue": null }, { "name": "att_name", "type": "esriFieldTypeString", "alias": "att_name", "domain": null, "editable": true, "nullable": false, "length": 250, "defaultValue": null }, { "name": "data_size", "type": "esriFieldTypeInteger", "alias": "data_size", "domain": null, "editable": true, "nullable": false, "defaultValue": null }, { "name": "content_type", "type": "esriFieldTypeString", "alias": "content_type", "domain": null, "editable": true, "nullable": false, "length": 150, "defaultValue": null } ], "standardMaxRecordCount": 32000, "tileMaxRecordCount": 8000, "standardMaxRecordCountNoGeometry": 32000, "maxRecordCountFactor": 1 }