{ "currentVersion": 10.91, "cimVersion": "2.9.0", "id": 100038, "name": "Medium Voltage Transformer", "type": "Feature Layer", "parentLayer": { "id": 0, "name": "Electric Device" }, "defaultVisibility": true, "minScale": 3000, "maxScale": 0, "canScaleSymbols": false, "geometryType": "esriGeometryPoint", "description": "", "copyrightText": "", "editFieldsInfo": { "creationDateField": "CREATIONDATE", "creatorField": "CREATOR", "editDateField": "LASTUPDATE", "editorField": "UPDATEDBY" }, "ownershipBasedAccessControlForFeatures": null, "syncCanReturnChanges": true, "relationships": [], "isDataVersioned": true, "isDataArchived": false, "infoInEstimates": [ "extent" ], "isDataBranchVersioned": false, "isDataReplicaTracked": false, "isCoGoEnabled": false, "supportsRollbackOnFailureParameter": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "supportsValidateSQL": true, "supportsCoordinatesQuantization": true, "supportsQuantizationEditMode": true, "supportsCalculate": true, "supportsASyncCalculate": true, "supportsDatumTransformation": true, "advancedQueryCapabilities": { "supportsPagination": true, "supportsTrueCurve": true, "supportsQueryWithDistance": true, "supportsReturningQueryExtent": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryWithResultType": true, "supportsReturningGeometryCentroid": false, "supportsSqlExpression": true, "supportsQueryWithDatumTransformation": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsQueryAnalytic": true }, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "advancedEditingCapabilities": { "supportedSqlFormatsInCalculate": [ "standard" ], "supportsAsyncApplyEdits": true }, "hasMetadata": true, "extent": { "xmin": 6477595.607926726, "ymin": 1787269.7289284766, "xmax": 6490051.951124221, "ymax": 1804201.3020206392, "spatialReference": { "wkid": 103004, "latestWkid": 6418, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -115211800, "falseY": -93821500, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "sourceSpatialReference": { "wkid": 103004, "latestWkid": 6418, "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -115211800, "falseY": -93821500, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "assettype", "defaultSymbol": { "type": "esriSMS", "style": "esriSMSCircle", "color": [ 255, 255, 255, 255 ], "size": 12.75, "angle": 0, "xoffset": 0, "yoffset": 0, "outline": { "color": [ 0, 0, 0, 255 ], "width": 0.5 } }, "defaultLabel": "Other", "uniqueValueInfos": [ { "symbol": { "type": "esriPMS", "url": "1dfe2b968eecd2f5829ad40ac4a9fb0a", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "0", "label": "Unknown" }, { "symbol": { "type": "esriPMS", "url": "a36b8bef88301bb868b19b6f1ddd8733", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "781", "label": "Grounding Transformer" }, { "symbol": { "type": "esriPMS", "url": "df92bd10ed063920a42096893ab9e3d5", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "782", "label": "Mobile Single Phase" }, { "symbol": { "type": "esriPMS", "url": "1545b3fb2c005d853b8d2d98c8449d28", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "783", "label": "Mobile Three Phase" }, { "symbol": { "type": "esriPMS", "url": "a36b8bef88301bb868b19b6f1ddd8733", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "784", "label": "Network" }, { "symbol": { "type": "esriPMS", "url": "d39f631e5afacdaa50087537215bac9d", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "785", "label": "Overhead Single Phase" }, { "symbol": { "type": "esriPMS", "url": "4c1f30b9d80bb24e8140f74b0a43391b", "imageData": "iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAD8ElEQVRIic2WMWjbWBjH/6lsPU5GPhQ7NLYbrgeHAgk9AvESQ4u7ZHICoZ2CwVnCQdZumbLEW9ZA6qW9hm4hgw035IZCiScXugULWhoSqTY5Y2Mh5yRbzg3SsyVLDoGWch8I670nfT//v/d931MAP9gC/3cgCyDquAeAhv2rfk9gHEAMAO+z9tAB/ApA+RZgxHboBxo13r5iAL5gqPzOwDgAkQ4WcjlxJpVK8YnEEsOyESYYjACAoWmS3mpJlf39V+flcsOGPgIgwUftOOAA9ksqFUlubW3wiUQGAGY5Dpf/3sOvPwUwxU6gSoiohELi093djCrLpaNsds/2Qf+sC+oHjNCHF3I5UVxd3eAmJ5eS4TAWeR5xQpD/3EWxfoM/f2eRFgSopol3zSYqQGa9VBJP8/ltW60Ia2/V24APqTJxdXXjt1hsKS0ImOU4AMCZ1sdx3QQAHNdNrN1nwDMMVqJRLPI8DmRZfLKzc/Bmefm57e8RgPI4YBx2giS3tja4yUkXDAAKF73B/cvLHtbuM8OXCcH69DTe1mqRZ4eHL+zwsrZfxQ8Yo6HkE4lMMhx2wc60Pt43+4PxP8bNQCW1WY5DMhxGBcgs5HLFj69fS7ZfD5Cl6mZSqRQALPLuanCqG6cSANKCgEq7jan5eRFWtvK2f8MJpB0EfCKxNMtxiBPiUrc5E8DmjIeJ980+Hgv3BmOeYRAnBMbc3AqAEp0G0PAtC4ZlI3zAvXRcNzHFTmDzgXv+TOsj/7mLvxaJaz5OCJRQSHRMEcAbUgsYDEZ4ZhgmZ2aOAgsXPd+9dL7v9H+nXurcu8JlbwA9rpuDJPLbS7Pb9bQ3J7ABuwYNTZOqhIhpQfBk5ssLN5DaqMpqpwNdVSWHf3WsQr3VkpRQSFRNE4UL07NeuOwhGpzAmdZ3zVOViq5D0XWY19dOhcYokLYgvrK//+rp7m7mXbOJKPuzJ1RXxg2iwQnPPGBlbMu0Otmnk5PiiG+Pwq8A+PNyuaHKcqkCZP5I8K7ycNoavMBqp4O/a22oslyyi576hR9QgX3QHmWze+ulknggy+L69LSr44yzaqeD4tUVDE2THKeGCseJ4beHX2A1XJzm89tPdnYO3tZqkWQ4jLQg+KU7FF3HB1VFpd2GoWnSaT6/PeJvYH7ABqx2JJ6Xy403y8vPnx0evqgAmUq7jTghiBMyAFc7HSi6bklxn4cU5iqNcXVIQyACwFE2u7eQyxWn5udFY25uhXYQs9tt6KoqmdfXjU8nJ0XHnlGYS91tQApVYYWXtZ1JGPbGcab6KbsLkL5cxu1fbc5nv/mrjZpiX/QIIxj2XhVWUX/X71JqBsaE6q72Hy1LnaSR5lc3AAAAAElFTkSuQmCC", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "788", "label": "Overhead Three Phase" }, { "symbol": { "type": "esriPMS", "url": "a36b8bef88301bb868b19b6f1ddd8733", "imageData": "iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAADvklEQVRIic2WMWjbWBjH/+DmlRSrAesCluWSLn4lMYWoKhwRtLRDAgdOhku7BINNhwxZc1OmLPGW5YZAt5SGLiWTDTd4CYQICjU+OEpBoVBDZXnRkePJtFFo6aD3bMmW3Rwtx/1BWH56+n76v/e+770r+I915f8OJAB+Ct0DgMt/2Y8EZgAoAKSYZzdDQAdA+3uAMg8YBxqUxC8FwHv0nV8amAFAxZ/5UoneMAxDUtWFBCFyYmJCBgC/27XOz86s13t7+y3TdDn0NgALMW5HAXuwGcOQ725slCVVLQCAe2rB9xh8L5gyOUeppKr04c5Ogdl27bBY3OUxxMdGoHFAWXSeL5UoXVkpX0ulFpxmA06zAa/TBslSEPUWvFdVtI6PQJISZu49gKLphbVajZ5UKlvcLUUwt2wc8KZwRldWyl/8TwtvXr6Ae2r1OkwtlntAAPA9htM/qnCaDdx5sk7vb28/fb609Ih3vw3AHAXMgC+Quxsb5Wup1BAs+fMyJmeN3r2AAoDXaePNyxfIP16TVw8ONvnwEh63HQdUxFBKqlpwmo0ITECEUqubESAQzLHTbEDR9MJ8qVT989kzi8cdAhLh7oZhGADgNBtDMJKlkbapxTL+qe9H2lrHR1A0HdP5PEWwWiUe3w8DRQWBpKoL7qkFrxNd1WF3YeDHtyb8D/2R8D0Gr9PG9NzcMoCaCAvAjU2LBCGyWPbj3IWf/f1hN9LGHAdKOhN+4SowPKQBcGIiAkxcl2PdhYHeq+qQywGRQeBITc4aI90JpX79DZ3f1yNtny8uhspbGOiC56Df7VpyjtLW8RFIlmJqsfzNjyJZCpKlPZdyjuKcsfASZ4PAns7PzixJVSlJSpicNZC4Ln8TCPRdJtMZJNMZMNsOO/QHgaIESa/39vYf7uwUZu49QOsvEx/fmvg3UjQdAPCuXhdJ2itvgw4dAFLLNF1m2zVF0wuifl5Wco5C0XQw267xpBdxEQdsg2+0h8Xi7lqtRu88WaeD5W0cLPfLMvxu1wrtGgyhHSNuDt8jKLg4qVS27m9vP80/XpOdZgOt46O45Y5kOgNF06FoOvxu1zqpVLYG4vUUB3QRlCPaMk33+dLSo9WDg01F0wuKpsPrtMEcJ7wfIpnOBFai+6GARVJjVB6KIaAAcFgs7s6XStXpfJ5Oz80tiwry+eLCPWfMYrbtvqvXq6E5E7CIu3FAAWUIhpfwYBb6tXGUWJyzywDFyybGn9rCfb/71CbU5pfYwq6iX3sZgqT+oedSIR8jhuqy+gp7pYTcc9FRZAAAAABJRU5ErkJggg==", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "789", "label": "Pad Mounted Single Phase" }, { "symbol": { "type": "esriPMS", "url": "7aa9e6398c51bf5bfa7b617c99eb54c2", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "792", "label": "Pad Mounted Three Phase" }, { "symbol": { "type": "esriPMS", "url": "676955ed08e61f157f7454be2517c556", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "793", "label": "Subsurface Single Phase" }, { "symbol": { "type": "esriPMS", "url": "c36f8381d7e8c986de1e80990b5795e4", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "794", "label": "Subsurface Three Phase" }, { "symbol": { "type": "esriPMS", "url": "4c1f30b9d80bb24e8140f74b0a43391b", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "795", "label": "Overhead Three Phase Open Delta" }, { "symbol": { "type": "esriPMS", "url": "4c1f30b9d80bb24e8140f74b0a43391b", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "796", "label": "Overhead Three Phase Open Wye" }, { "symbol": { "type": "esriPMS", "url": "7aa9e6398c51bf5bfa7b617c99eb54c2", "imageData": "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", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "797", "label": "Pad Mounted Three Phase Open Delta" }, { "symbol": { "type": "esriPMS", "url": "7aa9e6398c51bf5bfa7b617c99eb54c2", "imageData": "iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAD4ElEQVRIic2WP2jbWBzHv+BGpUVqD+sCluWSwOEHjSlEdSFE0NIO9XFgZ0m7BINNhwxZs2XKcPGWpUOgHY6Uhi4lkw03eAmECAI1vqXcoVCoB1leBGmeTC8KPm6Qnqx/DoGW434grPcs/T7v+3u/3+/pGv5ju/Z/B3IAfgzcA4Dl/dLvCcwCkAAICf/NBoAmgP63AEXPYRIoaoJ3SQA+Y6z8ysAsAMIG87UauaOqqiDLiymOE1NTUyIAOMOhfn56qn/Y2dntaZrlQe8B0JGgdhLQh82oqvhgba0uyHIZAKwTHfhBwtf+XxidWRDzhAiyTJ5sbZWpYbT2q9VtzwdbbAiaBBTZw/O1GiFLS/Wb6fSi2e3A7HZgD/pIL6+D++lnDF6uond4AI4XMPPwMSSlWF5ptchRo7HhqSVw95ZeBpxlysjSUv0f5+/Fj+/fucoAcDkCfqECAOAXKrCPm3BsipPfmzC7Hdx/sUoebW6+elsqPfP83QOgTQJm4SXIg7W1+s10OgQDgNtP66F7+7jpj+1BHx/fv0Ph+Yq4vLe37oWX8/z2k4ASC6Ugy2Wz2wnBuBzBjbuqP07dEn2VzKwTHWa3A0kpludrteYfb97ont8YkGPq7qiqCgBmtxNaTVDdJJUA0Ds8gKQUMV0oELjZKnj+nSCQdRAIsrxoneiwB+ME43IEX9q7+NLejUFv3FXx9U9/m+DYFPagj+m5uQqAFnMLwEosixTHiY4d7lT8QgWjMysG5HIE6eV1GL9qoXlqmpAyWRKYug7EQ+oCp6ZCwGBmRoG3n9YT9zK6YOb/Sr00mpkMyi9U/CRK2svRxUWsvQWBFrwadIZDXcwT0js8iGVmFMgsqlLME5xTOk5xr/gTFZ6fnuqCLBOOFyZm5ujMApcjsXn7uAk+kwWfyYIaRlChEwWyFiR82NnZfbK1VZ55+BjWmRULVeqWiFHCPOBmrDQrAgA+tdvsAb+9RRWaAISeplnUMFqSUiybv70OlUfIjuNTYp5AUkqghtHyip75RRKwD++g3a9Wt1daLXL/xSqJtrdJJuYJ8r9U4AyHeuDUoAicGEl7+Bluw8VRo7HxaHPzVeH5imh2O+gdHiSlO/hMFpJShKQU4QyH+lGjsRHx51sS0ILbjkhP06y3pdKz5b29dUkpliWlCHvQBzVNHyzmCfhM1pUSPg8ZLFQak+qQhYAAwH61uj1fqzWnCwUyPTdXYR1kdHFhnVOqU8OwPrXbzcCeMVhI3WVABqVww8t5znSMe+Mko0nKrgJkL2u4/Kst+Ow3f7Ux63sXO8KuY9x7Kdyi/q7fpcwcTAjVVe1fVEieqZgK9YYAAAAASUVORK5CYII=", "contentType": "image/png", "width": 21, "height": 21, "angle": 0, "xoffset": 0, "yoffset": 0 }, "value": "798", "label": "Pad Mounted Three Phase Open Wye" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 194, 219, 255 ], "toColor": [ 252, 194, 219, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 189, 255 ], "toColor": [ 179, 252, 189, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 199, 244, 252, 255 ], "toColor": [ 199, 244, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 188, 182, 252, 255 ], "toColor": [ 188, 182, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 223, 184, 255 ], "toColor": [ 252, 223, 184, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 246, 179, 252, 255 ], "toColor": [ 246, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 210, 252, 223, 255 ], "toColor": [ 210, 252, 223, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 213, 252, 255 ], "toColor": [ 212, 213, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 244, 252, 179, 255 ], "toColor": [ 244, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 248, 204, 252, 255 ], "toColor": [ 248, 204, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 191, 182, 255 ], "toColor": [ 252, 191, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 251, 252, 215, 255 ], "toColor": [ 251, 252, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 216, 204, 255 ], "toColor": [ 252, 216, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 217, 182, 252, 255 ], "toColor": [ 217, 182, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 211, 252, 187, 255 ], "toColor": [ 211, 252, 187, 255 ] } ] } }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.symbolrotation", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "hasM": true, "hasZ": true, "enableZDefaults": true, "zDefault": 0, "supportsVCSProjection": true, "allowUpdateWithoutMValues": false, "allowGeometryUpdates": true, "allowTrueCurvesUpdates": true, "onlyAllowTrueCurveUpdatesByTrueCurveClients": true, "hasAttachments": true, "supportsAttachmentsByUploadId": true, "supportsApplyEditsWithGlobalIds": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "objectIdField": "OBJECTID", "globalIdField": "GlobalID_1", "displayField": "subnetworkcontrollername", "typeIdField": "assettype", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null, "editable": false, "nullable": false, "defaultValue": null, "modelName": "OBJECTID" }, { "name": "assetgroup", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null, "editable": true, "nullable": false, "defaultValue": 0, "modelName": "assetgroup" }, { "name": "assettype", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null, "editable": true, "nullable": false, "defaultValue": null, "modelName": "assettype" }, { "name": "associationstatus", "type": "esriFieldTypeSmallInteger", "alias": "Association status", "domain": { "type": "codedValue", "name": "Network_5_AssociationStatus", "description": "Indicates how the feature participates in associations.", "codedValues": [ { "name": "None", "code": 0 }, { "name": "Container", "code": 1 }, { "name": "Structure", "code": 2 }, { "name": "Content", "code": 4 }, { "name": "Content and Container", "code": 5 }, { "name": "Content and Structure", "code": 6 }, { "name": "Attachment", "code": 8 }, { "name": "Attachment and Container", "code": 9 }, { "name": "Attachment and Structure", "code": 10 }, { "name": "Attachment and Content", "code": 12 }, { "name": "Attachment and Content and Container", "code": 13 }, { "name": "Attachment and Content and Structure", "code": 14 }, { "name": "Visible Content", "code": 16 }, { "name": "Visible Content and Container", "code": 17 }, { "name": "Visible Content and Structure", "code": 18 }, { "name": "Visible Content and Attachment", "code": 24 }, { "name": "Visible Content and Attachment and Container", "code": 25 }, { "name": "Visible Content and Attachment and Structure", "code": 26 }, { "name": "Connectivity", "code": 32 }, { "name": "Connectivity and Container", "code": 33 }, { "name": "Connectivity and Structure", "code": 34 }, { "name": "Connectivity and Content", "code": 36 }, { "name": "Connectivity and Content and Container", "code": 37 }, { "name": "Connectivity and Content and Structure", "code": 38 }, { "name": "Connectivity and Attachment", "code": 40 }, { "name": "Connectivity and Attachment and Container", "code": 41 }, { "name": "Connectivity and Attachment and Structure", "code": 42 }, { "name": "Connectivity and Attachment and Content", "code": 44 }, { "name": "Connectivity and Attachment and Content and Container", "code": 45 }, { "name": "Connectivity and Attachment and Content and Structure", "code": 46 }, { "name": "Connectivity and Visible Content", "code": 48 }, { "name": "Connectivity and Visible Content and Container", "code": 49 }, { "name": "Connectivity and Visible Content and Structure", "code": 50 }, { "name": "Connectivity and Visible Content and Attachment", "code": 56 }, { "name": "Connectivity and Visible Content and Attachment and Container", "code": 57 }, { "name": "Connectivity and Visible Content and Attachment and Structure", "code": 58 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": false, "nullable": false, "defaultValue": 0, "modelName": "associationstatus" }, { "name": "isconnected", "type": "esriFieldTypeSmallInteger", "alias": "Is connected", "domain": { "type": "codedValue", "name": "Network_5_IsConnected", "description": "Indicates if the feature is connected to a subnetwork controller.", "codedValues": [ { "name": "False", "code": 0 }, { "name": "True", "code": 1 }, { "name": "Unknown", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": false, "nullable": false, "defaultValue": 2, "modelName": "isconnected" }, { "name": "subnetworkcontrollername", "type": "esriFieldTypeString", "alias": "Subnetwork controller name", "domain": null, "editable": false, "nullable": false, "length": 2000, "defaultValue": "Unknown", "modelName": "subnetworkcontrollername" }, { "name": "terminalconfiguration", "type": "esriFieldTypeString", "alias": "Terminal Configuration", "domain": null, "editable": true, "nullable": false, "length": 128, "defaultValue": "Default", "modelName": "terminalconfiguration" }, { "name": "creationdate", "type": "esriFieldTypeDate", "alias": "Creation date", "domain": null, "editable": false, "nullable": true, "length": 8, "defaultValue": null, "modelName": "creationdate" }, { "name": "creator", "type": "esriFieldTypeString", "alias": "Creator", "domain": null, "editable": false, "nullable": true, "length": 255, "defaultValue": null, "modelName": "creator" }, { "name": "lastupdate", "type": "esriFieldTypeDate", "alias": "Last update", "domain": null, "editable": false, "nullable": true, "length": 8, "defaultValue": null, "modelName": "lastupdate" }, { "name": "updatedby", "type": "esriFieldTypeString", "alias": "Updated by", "domain": null, "editable": false, "nullable": true, "length": 255, "defaultValue": null, "modelName": "updatedby" }, { "name": "globalid", "type": "esriFieldTypeGUID", "alias": "Global ID", "domain": null, "editable": false, "nullable": false, "length": 38, "defaultValue": null, "modelName": "globalid" }, { "name": "subnetworkname", "type": "esriFieldTypeString", "alias": "subnetworkname", "domain": { "type": "codedValue", "name": "IE_SubnetworkID", "description": "IE Subnetwork ID's", "codedValues": [ { "name": "A-111", "code": "A-111" }, { "name": "A-112", "code": "A-112" }, { "name": "A-113", "code": "A-113" }, { "name": "A1-30 Splice", "code": "A1-30 Splice" }, { "name": "B10-113", "code": "B10-113" }, { "name": "B10-114", "code": "B10-114" }, { "name": "B10-115", "code": "B10-115" }, { "name": "B10-116", "code": "B10-116" }, { "name": "B-111", "code": "B-111" }, { "name": "B-112", "code": "B-112" }, { "name": "B19-DD4-112", "code": "B19-DD4-112" }, { "name": "B6-113", "code": "B6-113" }, { "name": "B6-114", "code": "B6-114" }, { "name": "B6-B7-111", "code": "B6-B7-111" }, { "name": "B8-B9-112", "code": "B8-B9-112" }, { "name": "B9-113", "code": "B9-113" }, { "name": "B9-114", "code": "B9-114" }, { "name": "B9-115", "code": "B9-115" }, { "name": "B9-116", "code": "B9-116" }, { "name": "B9-117", "code": "B9-117" }, { "name": "B9-B10-111", "code": "B9-B10-111" }, { "name": "BERTH 10", "code": "BERTH 10" }, { "name": "BERTH 12", "code": "BERTH 12" }, { "name": "Berth 18", "code": "Berth 18" }, { "name": "Berth 19", "code": "Berth 19" }, { "name": "BERTH 6", "code": "BERTH 6" }, { "name": "BERTH 8", "code": "BERTH 8" }, { "name": "BERTH 9", "code": "BERTH 9" }, { "name": "BM-115", "code": "BM-115" }, { "name": "Bus Tie ", "code": "Bus Tie " }, { "name": "D-111", "code": "D-111" }, { "name": "D-113", "code": "D-113" }, { "name": "D-200", "code": "D-200" }, { "name": "D-201", "code": "D-201" }, { "name": "D-202", "code": "D-202" }, { "name": "D-206", "code": "D-206" }, { "name": "D-208", "code": "D-208" }, { "name": "D3-144-1", "code": "D3-144-1" }, { "name": "D3-144-2", "code": "D3-144-2" }, { "name": "D3-144-3", "code": "D3-144-3" }, { "name": "D3-144-4", "code": "D3-144-4" }, { "name": "D3-144-5", "code": "D3-144-5" }, { "name": "D-B6-112", "code": "D-B6-112" }, { "name": "DD1-113 ", "code": "DD1-113 " }, { "name": "DD1-114", "code": "DD1-114" }, { "name": "DD1-115", "code": "DD1-115" }, { "name": "DD1-116", "code": "DD1-116" }, { "name": "DD1-B12-111", "code": "DD1-B12-111" }, { "name": "DD3-113", "code": "DD3-113" }, { "name": "DD3-114", "code": "DD3-114" }, { "name": "DD3-115", "code": "DD3-115" }, { "name": "DD3-DD4-111", "code": "DD3-DD4-111" }, { "name": "DD4-113", "code": "DD4-113" }, { "name": "DD4-114", "code": "DD4-114" }, { "name": "DD4-115", "code": "DD4-115" }, { "name": "DD4-116", "code": "DD4-116" }, { "name": "DM-116", "code": "DM-116" }, { "name": "Dry Dock 1", "code": "Dry Dock 1" }, { "name": "Dry Dock 3", "code": "Dry Dock 3" }, { "name": "Dry Dock 4", "code": "Dry Dock 4" }, { "name": "E-B10-119", "code": "E-B10-119" }, { "name": "EB-115", "code": "EB-115" }, { "name": "ED-116", "code": "ED-116" }, { "name": "EH-118-1", "code": "EH-118-1" }, { "name": "EH-118-2", "code": "EH-118-2" }, { "name": "EK-114", "code": "EK-114" }, { "name": "EP-117", "code": "EP-117" }, { "name": "FH-113", "code": "FH-113" }, { "name": "FJ-111", "code": "FJ-111" }, { "name": "G-111", "code": "G-111" }, { "name": "G-112 Bus", "code": "G-112 Bus" }, { "name": "G-113", "code": "G-113" }, { "name": "G-114 bus", "code": "G-114 bus" }, { "name": "G-115", "code": "G-115" }, { "name": "H-111", "code": "H-111" }, { "name": "H-112", "code": "H-112" }, { "name": "H-115", "code": "H-115" }, { "name": "HI-114", "code": "HI-114" }, { "name": "I-115", "code": "I-115" }, { "name": "I-844-112", "code": "I-844-112" }, { "name": "I-B18-116", "code": "I-B18-116" }, { "name": "I-B20-117", "code": "I-B20-117" }, { "name": "IL-111", "code": "IL-111" }, { "name": "J-112", "code": "J-112" }, { "name": "J-113", "code": "J-113" }, { "name": "J-114", "code": "J-114" }, { "name": "JL-111", "code": "JL-111" }, { "name": "K-111", "code": "K-111" }, { "name": "K-112", "code": "K-112" }, { "name": "K-113", "code": "K-113" }, { "name": "K-114", "code": "K-114" }, { "name": "K-115", "code": "K-115" }, { "name": "K-B12-117", "code": "K-B12-117" }, { "name": "K-DD3-116", "code": "K-DD3-116" }, { "name": "KO-114", "code": "KO-114" }, { "name": "L-113", "code": "L-113" }, { "name": "L-114", "code": "L-114" }, { "name": "l-115", "code": "l-115" }, { "name": "L-116", "code": "L-116" }, { "name": "L-117", "code": "L-117" }, { "name": "LTG XFMR", "code": "LTG XFMR" }, { "name": "M-111", "code": "M-111" }, { "name": "M-112", "code": "M-112" }, { "name": "M-200", "code": "M-200" }, { "name": "M-201", "code": "M-201" }, { "name": "M-206", "code": "M-206" }, { "name": "M-208", "code": "M-208" }, { "name": "M-210", "code": "M-210" }, { "name": "MN-114", "code": "MN-114" }, { "name": "N-112", "code": "N-112" }, { "name": "NT-3", "code": "NT-3" }, { "name": "P-111", "code": "P-111" }, { "name": "P-113", "code": "P-113" }, { "name": "P-114", "code": "P-114" }, { "name": "P-DD1-112", "code": "P-DD1-112" }, { "name": "PME 10 D2-56", "code": "PME 10 D2-56" }, { "name": "PME 10 D2-56-1", "code": "PME 10 D2-56-1" }, { "name": "PME 10 D2-56-2", "code": "PME 10 D2-56-2" }, { "name": "PME 10 D2-56-3", "code": "PME 10 D2-56-3" }, { "name": "PME 10 D2-56-4", "code": "PME 10 D2-56-4" }, { "name": "PME 10 D3-11", "code": "PME 10 D3-11" }, { "name": "PME 10 D3-11-1", "code": "PME 10 D3-11-1" }, { "name": "PME 10 D3-11-2", "code": "PME 10 D3-11-2" }, { "name": "PME 10 D3-11-3", "code": "PME 10 D3-11-3" }, { "name": "PME 10 D3-11-4", "code": "PME 10 D3-11-4" }, { "name": "PME 10 E2-73", "code": "PME 10 E2-73" }, { "name": "PME 10 E2-73-1", "code": "PME 10 E2-73-1" }, { "name": "PME 10 E2-73-2", "code": "PME 10 E2-73-2" }, { "name": "PME 10 E2-73-3", "code": "PME 10 E2-73-3" }, { "name": "PME 10 E2-73-4", "code": "PME 10 E2-73-4" }, { "name": "PME 10 G2-59", "code": "PME 10 G2-59" }, { "name": "PME 11 E2-72", "code": "PME 11 E2-72" }, { "name": "PME 11 E2-72-1", "code": "PME 11 E2-72-1" }, { "name": "PME 11 E2-72-2", "code": "PME 11 E2-72-2" }, { "name": "PME 11 E2-72-3 (fused)", "code": "PME 11 E2-72-3 (fused)" }, { "name": "PME 11 E2-72-4", "code": "PME 11 E2-72-4" }, { "name": "PME 11 F1-65", "code": "PME 11 F1-65" }, { "name": "PME 11 F1-65-1", "code": "PME 11 F1-65-1" }, { "name": "PME 11 F1-65-2", "code": "PME 11 F1-65-2" }, { "name": "PME 11 F1-65-3", "code": "PME 11 F1-65-3" }, { "name": "PME 11 F1-65-4", "code": "PME 11 F1-65-4" }, { "name": "PME 11 F3-5", "code": "PME 11 F3-5" }, { "name": "PME 11 F3-5-1", "code": "PME 11 F3-5-1" }, { "name": "PME 11 F3-5-2", "code": "PME 11 F3-5-2" }, { "name": "PME 11 F3-5-3", "code": "PME 11 F3-5-3" }, { "name": "PME 11 F3-5-4", "code": "PME 11 F3-5-4" }, { "name": "PME 11 G2-58", "code": "PME 11 G2-58" }, { "name": "PME 11 G2-58-1", "code": "PME 11 G2-58-1" }, { "name": "PME 11 G2-58-2", "code": "PME 11 G2-58-2" }, { "name": "PME 11 G2-58-3 (fused)", "code": "PME 11 G2-58-3 (fused)" }, { "name": "PME 11 G2-58-4", "code": "PME 11 G2-58-4" }, { "name": "PME 11 G2-59-1", "code": "PME 11 G2-59-1" }, { "name": "PME 11 G2-59-2", "code": "PME 11 G2-59-2" }, { "name": "PME 11 G2-59-3", "code": "PME 11 G2-59-3" }, { "name": "PME 11 G2-59-4", "code": "PME 11 G2-59-4" }, { "name": "PME 12 K3-8", "code": "PME 12 K3-8" }, { "name": "PME 12 K3-8-1", "code": "PME 12 K3-8-1" }, { "name": "PME 12 K3-8-2\n(fused)", "code": "PME 12 K3-8-2\n(fused)" }, { "name": "PME 12 K3-8-3\n(fused)", "code": "PME 12 K3-8-3\n(fused)" }, { "name": "PME 12 K3-8-4", "code": "PME 12 K3-8-4" }, { "name": "PME 9 D1-124", "code": "PME 9 D1-124" }, { "name": "PME 9 D1-124-1", "code": "PME 9 D1-124-1" }, { "name": "PME 9 D1-124-2", "code": "PME 9 D1-124-2" }, { "name": "PME 9 D1-124-3", "code": "PME 9 D1-124-3" }, { "name": "PME 9 D1-124-4", "code": "PME 9 D1-124-4" }, { "name": "PME 9 D1-126", "code": "PME 9 D1-126" }, { "name": "PME 9 D1-126-1", "code": "PME 9 D1-126-1" }, { "name": "PME 9 D1-126-2", "code": "PME 9 D1-126-2" }, { "name": "PME 9 D1-126-3", "code": "PME 9 D1-126-3" }, { "name": "PME 9 D1-126-4", "code": "PME 9 D1-126-4" }, { "name": "PME 9 D1-72", "code": "PME 9 D1-72" }, { "name": "PME 9 D1-72-1", "code": "PME 9 D1-72-1" }, { "name": "PME 9 D1-72-2", "code": "PME 9 D1-72-2" }, { "name": "PME 9 D1-72-3", "code": "PME 9 D1-72-3" }, { "name": "PME 9 D1-72-4", "code": "PME 9 D1-72-4" }, { "name": "PME 9 D2-142", "code": "PME 9 D2-142" }, { "name": "PME 9 D2-142-1", "code": "PME 9 D2-142-1" }, { "name": "PME 9 D2-142-2", "code": "PME 9 D2-142-2" }, { "name": "PME 9 D2-142-3", "code": "PME 9 D2-142-3" }, { "name": "PME 9 D2-142-4", "code": "PME 9 D2-142-4" }, { "name": "PME 9 D3-9", "code": "PME 9 D3-9" }, { "name": "PME 9 D3-9-1", "code": "PME 9 D3-9-1" }, { "name": "PME 9 D3-9-2", "code": "PME 9 D3-9-2" }, { "name": "PME 9 D3-9-3", "code": "PME 9 D3-9-3" }, { "name": "PME 9 D3-9-4", "code": "PME 9 D3-9-4" }, { "name": "PME 9 G1-84", "code": "PME 9 G1-84" }, { "name": "PME 9 G1-84-1", "code": "PME 9 G1-84-1" }, { "name": "PME 9 G1-84-2", "code": "PME 9 G1-84-2" }, { "name": "PME 9 G1-84-3", "code": "PME 9 G1-84-3" }, { "name": "PME 9 G1-84-4", "code": "PME 9 G1-84-4" }, { "name": "PME-10-G1-E1", "code": "PME-10-G1-E1" }, { "name": "PME-10-G1-E1-1", "code": "PME-10-G1-E1-1" }, { "name": "PME-10-G1-E1-2", "code": "PME-10-G1-E1-2" }, { "name": "PME-10-G1-E1-3", "code": "PME-10-G1-E1-3" }, { "name": "PME-10-G1-E1-4", "code": "PME-10-G1-E1-4" }, { "name": "PME-10-G1-E2", "code": "PME-10-G1-E2" }, { "name": "PME-10-G1-E2-1", "code": "PME-10-G1-E2-1" }, { "name": "PME-10-G1-E2-2", "code": "PME-10-G1-E2-2" }, { "name": "PME-10-G1-E2-3", "code": "PME-10-G1-E2-3" }, { "name": "PME-10-G1-E2-4", "code": "PME-10-G1-E2-4" }, { "name": "RA-100", "code": "RA-100" }, { "name": "RA-100-1", "code": "RA-100-1" }, { "name": "RA-100-2", "code": "RA-100-2" }, { "name": "RA-100-3", "code": "RA-100-3" }, { "name": "RA-100-4", "code": "RA-100-4" }, { "name": "RA-100-5", "code": "RA-100-5" }, { "name": "RA-102", "code": "RA-102" }, { "name": "RA-102-1", "code": "RA-102-1" }, { "name": "RA-102-2", "code": "RA-102-2" }, { "name": "RA-102-3", "code": "RA-102-3" }, { "name": "RA-102-4", "code": "RA-102-4" }, { "name": "RA-104", "code": "RA-104" }, { "name": "RA-104-1", "code": "RA-104-1" }, { "name": "RA-104-2", "code": "RA-104-2" }, { "name": "RA-104-3", "code": "RA-104-3" }, { "name": "RA-104-4", "code": "RA-104-4" }, { "name": "RA-106", "code": "RA-106" }, { "name": "RA-106-1", "code": "RA-106-1" }, { "name": "RA-106-2", "code": "RA-106-2" }, { "name": "RA-106-3", "code": "RA-106-3" }, { "name": "RA-106-4", "code": "RA-106-4" }, { "name": "RA-106-5", "code": "RA-106-5" }, { "name": "RA-107", "code": "RA-107" }, { "name": "RA-107-1", "code": "RA-107-1" }, { "name": "RA-107-2", "code": "RA-107-2" }, { "name": "RA-107-3", "code": "RA-107-3" }, { "name": "RA-107-4", "code": "RA-107-4" }, { "name": "RA-108", "code": "RA-108" }, { "name": "RA-108-1", "code": "RA-108-1" }, { "name": "RA-108-2", "code": "RA-108-2" }, { "name": "RA-108-3", "code": "RA-108-3" }, { "name": "RA-108-4", "code": "RA-108-4" }, { "name": "RA-108-5", "code": "RA-108-5" }, { "name": "RA-111", "code": "RA-111" }, { "name": "RA-111-1", "code": "RA-111-1" }, { "name": "RA-111-2", "code": "RA-111-2" }, { "name": "RA-111-3", "code": "RA-111-3" }, { "name": "RA-111-4", "code": "RA-111-4" }, { "name": "RA-112", "code": "RA-112" }, { "name": "RA-112-1", "code": "RA-112-1" }, { "name": "RA-112-2", "code": "RA-112-2" }, { "name": "RA-112-3", "code": "RA-112-3" }, { "name": "RA-112-4", "code": "RA-112-4" }, { "name": "RA-112-5", "code": "RA-112-5" }, { "name": "RA-113", "code": "RA-113" }, { "name": "RA-113-1", "code": "RA-113-1" }, { "name": "RA-113-2", "code": "RA-113-2" }, { "name": "RA-113-3", "code": "RA-113-3" }, { "name": "RA-113-4", "code": "RA-113-4" }, { "name": "RA-113-5", "code": "RA-113-5" }, { "name": "RA-113-6", "code": "RA-113-6" }, { "name": "RA-115", "code": "RA-115" }, { "name": "RA-115-1", "code": "RA-115-1" }, { "name": "RA-115-2", "code": "RA-115-2" }, { "name": "RA-115-3", "code": "RA-115-3" }, { "name": "RA-115-4", "code": "RA-115-4" }, { "name": "RA-115-5", "code": "RA-115-5" }, { "name": "RA-115-6", "code": "RA-115-6" }, { "name": "RA-117", "code": "RA-117" }, { "name": "RA-117-1", "code": "RA-117-1" }, { "name": "RA-117-2", "code": "RA-117-2" }, { "name": "RA-117-3", "code": "RA-117-3" }, { "name": "RA-117-4", "code": "RA-117-4" }, { "name": "RA-117-5", "code": "RA-117-5" }, { "name": "RA-117-6", "code": "RA-117-6" }, { "name": "RA-119", "code": "RA-119" }, { "name": "RA-119-1", "code": "RA-119-1" }, { "name": "RA-119-2", "code": "RA-119-2" }, { "name": "RA-119-3", "code": "RA-119-3" }, { "name": "RA-120", "code": "RA-120" }, { "name": "RA-120-1", "code": "RA-120-1" }, { "name": "RA-120-2", "code": "RA-120-2" }, { "name": "RA-120-3", "code": "RA-120-3" }, { "name": "RA-120-4", "code": "RA-120-4" }, { "name": "RA-121", "code": "RA-121" }, { "name": "RA-121-1", "code": "RA-121-1" }, { "name": "RA-121-2", "code": "RA-121-2" }, { "name": "RA-121-3", "code": "RA-121-3" }, { "name": "RA-121-4", "code": "RA-121-4" }, { "name": "RA-121-5", "code": "RA-121-5" }, { "name": "RA-121-6", "code": "RA-121-6" }, { "name": "RA-122", "code": "RA-122" }, { "name": "RA-122-1", "code": "RA-122-1" }, { "name": "RA-122-2", "code": "RA-122-2" }, { "name": "RA-122-3", "code": "RA-122-3" }, { "name": "RA-122-4", "code": "RA-122-4" }, { "name": "RA-122-5", "code": "RA-122-5" }, { "name": "RA-122-6", "code": "RA-122-6" }, { "name": "RA-123", "code": "RA-123" }, { "name": "RA-123-1", "code": "RA-123-1" }, { "name": "RA-123-2", "code": "RA-123-2" }, { "name": "RA-123-3", "code": "RA-123-3" }, { "name": "RA-123-4", "code": "RA-123-4" }, { "name": "RA-123-5", "code": "RA-123-5" }, { "name": "RA-123-6", "code": "RA-123-6" }, { "name": "RA-125", "code": "RA-125" }, { "name": "RA-125-1", "code": "RA-125-1" }, { "name": "RA-125-2", "code": "RA-125-2" }, { "name": "RA-125-3", "code": "RA-125-3" }, { "name": "RA-125-4", "code": "RA-125-4" }, { "name": "RA-125-5", "code": "RA-125-5" }, { "name": "RA-125-6", "code": "RA-125-6" }, { "name": "RA-129", "code": "RA-129" }, { "name": "RA-129-1", "code": "RA-129-1" }, { "name": "RA-129-2", "code": "RA-129-2" }, { "name": "RA-129-3", "code": "RA-129-3" }, { "name": "RA-129-4", "code": "RA-129-4" }, { "name": "RA-129-5", "code": "RA-129-5" }, { "name": "RA-129-6", "code": "RA-129-6" }, { "name": "RA-130", "code": "RA-130" }, { "name": "RA-130-1", "code": "RA-130-1" }, { "name": "RA-130-2", "code": "RA-130-2" }, { "name": "RA-130-3", "code": "RA-130-3" }, { "name": "RA-130-4", "code": "RA-130-4" }, { "name": "RA-130-5", "code": "RA-130-5" }, { "name": "RA-131", "code": "RA-131" }, { "name": "RA-131-1", "code": "RA-131-1" }, { "name": "RA-131-2", "code": "RA-131-2" }, { "name": "RA-131-3", "code": "RA-131-3" }, { "name": "RA-131-4", "code": "RA-131-4" }, { "name": "RA-131-5", "code": "RA-131-5" }, { "name": "RA-131-6", "code": "RA-131-6" }, { "name": "RA-132", "code": "RA-132" }, { "name": "RA-132-1", "code": "RA-132-1" }, { "name": "RA-132-2", "code": "RA-132-2" }, { "name": "RA-132-3", "code": "RA-132-3" }, { "name": "RA-132-4", "code": "RA-132-4" }, { "name": "RA-132-5", "code": "RA-132-5" }, { "name": "RA-134", "code": "RA-134" }, { "name": "RA-134-1", "code": "RA-134-1" }, { "name": "RA-134-2", "code": "RA-134-2" }, { "name": "RA-134-3", "code": "RA-134-3" }, { "name": "RA-134-4", "code": "RA-134-4" }, { "name": "RA-134-5", "code": "RA-134-5" }, { "name": "RA-136", "code": "RA-136" }, { "name": "RA-136-1", "code": "RA-136-1" }, { "name": "RA-136-2", "code": "RA-136-2" }, { "name": "RA-136-3", "code": "RA-136-3" }, { "name": "RA-136-4", "code": "RA-136-4" }, { "name": "RA-136-5", "code": "RA-136-5" }, { "name": "RA-138", "code": "RA-138" }, { "name": "RA-138-1", "code": "RA-138-1" }, { "name": "RA-138-2", "code": "RA-138-2" }, { "name": "RA-138-3", "code": "RA-138-3" }, { "name": "RA-138-4", "code": "RA-138-4" }, { "name": "RA-138-5", "code": "RA-138-5" }, { "name": "RA-138A", "code": "RA-138A" }, { "name": "RA-138A-1", "code": "RA-138A-1" }, { "name": "RA-138A-2", "code": "RA-138A-2" }, { "name": "RA-138A-3", "code": "RA-138A-3" }, { "name": "RA-138A-4", "code": "RA-138A-4" }, { "name": "RA-138A-5", "code": "RA-138A-5" }, { "name": "RA-138A-6", "code": "RA-138A-6" }, { "name": "RA-146", "code": "RA-146" }, { "name": "RA-146-1", "code": "RA-146-1" }, { "name": "RA-146-2", "code": "RA-146-2" }, { "name": "RA-146-3", "code": "RA-146-3" }, { "name": "RA-146-4", "code": "RA-146-4" }, { "name": "RA-146-5", "code": "RA-146-5" }, { "name": "RA-146-6", "code": "RA-146-6" }, { "name": "RA-148", "code": "RA-148" }, { "name": "RA-148-1", "code": "RA-148-1" }, { "name": "RA-148-2", "code": "RA-148-2" }, { "name": "RA-148-3", "code": "RA-148-3" }, { "name": "RA-148-4", "code": "RA-148-4" }, { "name": "RA-148-5", "code": "RA-148-5" }, { "name": "RA-148-6", "code": "RA-148-6" }, { "name": "RA-152", "code": "RA-152" }, { "name": "RA-152-1", "code": "RA-152-1" }, { "name": "RA-152-2", "code": "RA-152-2" }, { "name": "RA-152-3", "code": "RA-152-3" }, { "name": "RA-152-4", "code": "RA-152-4" }, { "name": "RA-152-5", "code": "RA-152-5" }, { "name": "RA-152-6", "code": "RA-152-6" }, { "name": "RA-156", "code": "RA-156" }, { "name": "RA-156-1", "code": "RA-156-1" }, { "name": "RA-156-2", "code": "RA-156-2" }, { "name": "RA-156-3", "code": "RA-156-3" }, { "name": "RA-156-4", "code": "RA-156-4" }, { "name": "RA-156-5", "code": "RA-156-5" }, { "name": "RA-156-6", "code": "RA-156-6" }, { "name": "RA-158", "code": "RA-158" }, { "name": "RA-158-1", "code": "RA-158-1" }, { "name": "RA-158-2", "code": "RA-158-2" }, { "name": "RA-158-3", "code": "RA-158-3" }, { "name": "RA-158-4", "code": "RA-158-4" }, { "name": "RA-158-5", "code": "RA-158-5" }, { "name": "RA-158-6", "code": "RA-158-6" }, { "name": "RA-160", "code": "RA-160" }, { "name": "RA-160-1", "code": "RA-160-1" }, { "name": "RA-160-2", "code": "RA-160-2" }, { "name": "RA-160-3", "code": "RA-160-3" }, { "name": "RA-160-4", "code": "RA-160-4" }, { "name": "RA-160-5", "code": "RA-160-5" }, { "name": "RA-162", "code": "RA-162" }, { "name": "RA-162-1", "code": "RA-162-1" }, { "name": "RA-162-2", "code": "RA-162-2" }, { "name": "RA-162-3", "code": "RA-162-3" }, { "name": "RA-162-4", "code": "RA-162-4" }, { "name": "RA-162-5", "code": "RA-162-5" }, { "name": "RA-162-6", "code": "RA-162-6" }, { "name": "RA-21", "code": "RA-21" }, { "name": "RA-21-1", "code": "RA-21-1" }, { "name": "RA-21-2", "code": "RA-21-2" }, { "name": "RA-71", "code": "RA-71" }, { "name": "RA-71-1", "code": "RA-71-1" }, { "name": "RA-71-2", "code": "RA-71-2" }, { "name": "RA-71-3", "code": "RA-71-3" }, { "name": "RAD-114", "code": "RAD-114" }, { "name": "RAD-114-1", "code": "RAD-114-1" }, { "name": "RAD-114-2", "code": "RAD-114-2" }, { "name": "RAD-114-LOAD", "code": "RAD-114-LOAD" }, { "name": "RAD-116", "code": "RAD-116" }, { "name": "RAD-116-1", "code": "RAD-116-1" }, { "name": "RAD-116-2", "code": "RAD-116-2" }, { "name": "RAD-116-LOAD", "code": "RAD-116-LOAD" }, { "name": "RAD-118", "code": "RAD-118" }, { "name": "RAD-118-1", "code": "RAD-118-1" }, { "name": "RAD-118-2", "code": "RAD-118-2" }, { "name": "RAD-118-LOAD", "code": "RAD-118-LOAD" }, { "name": "Replaced", "code": "Replaced" }, { "name": "RS-109", "code": "RS-109" }, { "name": "RS-109-1", "code": "RS-109-1" }, { "name": "RS-109-2", "code": "RS-109-2" }, { "name": "RS-109-3", "code": "RS-109-3" }, { "name": "SEC CAB D3-144", "code": "SEC CAB D3-144" }, { "name": "SEC CAB G1-103", "code": "SEC CAB G1-103" }, { "name": "SEC CAB G1-103-1", "code": "SEC CAB G1-103-1" }, { "name": "SEC CAB G1-103-2", "code": "SEC CAB G1-103-2" }, { "name": "SEC CAB G1-103-3", "code": "SEC CAB G1-103-3" }, { "name": "SEC CAB G1-103-4", "code": "SEC CAB G1-103-4" }, { "name": "SEC CAB G1-103-5", "code": "SEC CAB G1-103-5" }, { "name": "SEC CAB G1-103-6", "code": "SEC CAB G1-103-6" }, { "name": "SEC CAB G1-105", "code": "SEC CAB G1-105" }, { "name": "SEC CAB G1-105-1", "code": "SEC CAB G1-105-1" }, { "name": "SEC CAB G1-105-2", "code": "SEC CAB G1-105-2" }, { "name": "SEC CAB G1-105-3", "code": "SEC CAB G1-105-3" }, { "name": "SEC CAB G1-105-4", "code": "SEC CAB G1-105-4" }, { "name": "SEC CAB G1-105-5", "code": "SEC CAB G1-105-5" }, { "name": "SEC CAB G1-105-6", "code": "SEC CAB G1-105-6" }, { "name": "Spare H1", "code": "Spare H1" }, { "name": "Spare H2", "code": "Spare H2" }, { "name": "STATION A ", "code": "STATION A " }, { "name": "STATION B ", "code": "STATION B " }, { "name": "Station D ", "code": "Station D " }, { "name": "STATION E ", "code": "STATION E " }, { "name": "STATION F ", "code": "STATION F " }, { "name": "STATION G ", "code": "STATION G " }, { "name": "STATION H ", "code": "STATION H " }, { "name": "STATION I ", "code": "STATION I " }, { "name": "STATION J ", "code": "STATION J " }, { "name": "STATION K ", "code": "STATION K " }, { "name": "Station K East", "code": "Station K East" }, { "name": "Station K West", "code": "Station K West" }, { "name": "STATION L ", "code": "STATION L " }, { "name": "Station M ", "code": "Station M " }, { "name": "STATION N ", "code": "STATION N " }, { "name": "STATION P ", "code": "STATION P " }, { "name": "Station 24", "code": "Station 24" }, { "name": "STATION 3", "code": "STATION 3" }, { "name": "SWGR RM XFMR", "code": "SWGR RM XFMR" }, { "name": "T-1", "code": "T-1" }, { "name": "T-2", "code": "T-2" }, { "name": "T-3", "code": "T-3" }, { "name": "T-body - 1", "code": "T-body - 1" }, { "name": "T-body - 2", "code": "T-body - 2" }, { "name": "VFI-F-1", "code": "VFI-F-1" }, { "name": "VFI-F-1-1", "code": "VFI-F-1-1" }, { "name": "VFI-F-1-2", "code": "VFI-F-1-2" }, { "name": "VFI-F-1-3", "code": "VFI-F-1-3" }, { "name": "VFI-F-1-4", "code": "VFI-F-1-4" }, { "name": "VFI-F-1-5", "code": "VFI-F-1-5" }, { "name": "VFI-F-1-6", "code": "VFI-F-1-6" }, { "name": "VFI-F-2", "code": "VFI-F-2" }, { "name": "VFI-F-2-1", "code": "VFI-F-2-1" }, { "name": "VFI-F-2-2", "code": "VFI-F-2-2" }, { "name": "VFI-F-2-3", "code": "VFI-F-2-3" }, { "name": "VFI-F-2-4", "code": "VFI-F-2-4" }, { "name": "VFI-F2-5", "code": "VFI-F2-5" }, { "name": "VFI-F-2-6", "code": "VFI-F-2-6" }, { "name": "VFI-G1-E1", "code": "VFI-G1-E1" }, { "name": "VFI-G1-E1-1", "code": "VFI-G1-E1-1" }, { "name": "VFI-G1-E1-2", "code": "VFI-G1-E1-2" }, { "name": "VFI-G1-E1-3", "code": "VFI-G1-E1-3" }, { "name": "VFI-G1-E1-4", "code": "VFI-G1-E1-4" }, { "name": "VFI-G1-E1-5", "code": "VFI-G1-E1-5" }, { "name": "VFI-G1-E1-6", "code": "VFI-G1-E1-6" }, { "name": "VFI-G1-E2-1", "code": "VFI-G1-E2-1" }, { "name": "VFI-G1-E2-2", "code": "VFI-G1-E2-2" }, { "name": "VFI-G1-E2-3", "code": "VFI-G1-E2-3" }, { "name": "VFI-G1-E2-4", "code": "VFI-G1-E2-4" }, { "name": "VFI-G1-E2-5", "code": "VFI-G1-E2-5" }, { "name": "VFI-G1-E2-6", "code": "VFI-G1-E2-6" }, { "name": "Other", "code": "Other" }, { "name": "B18-B19-111", "code": "B18-B19-111" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "editable": true, "nullable": false, "length": 2000, "defaultValue": null, "modelName": "subnetworkname" }, { "name": "assetid", "type": "esriFieldTypeString", "alias": "Asset ID", "domain": null, "editable": true, "nullable": true, "length": 64, "defaultValue": null, "modelName": "assetid" }, { "name": "phasesnormal", "type": "esriFieldTypeSmallInteger", "alias": "Phases Normal", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 7, "modelName": "phasesnormal" }, { "name": "phasescurrent", "type": "esriFieldTypeSmallInteger", "alias": "User Assigned Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 7, "modelName": "phasescurrent" }, { "name": "phasessummer", "type": "esriFieldTypeSmallInteger", "alias": "Summer Configuration Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 7, "modelName": "phasessummer" }, { "name": "phaseswinter", "type": "esriFieldTypeSmallInteger", "alias": "Winter Configuration Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 7, "modelName": "phaseswinter" }, { "name": "phasesplan", "type": "esriFieldTypeSmallInteger", "alias": "Planned Phases", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 7, "modelName": "phasesplan" }, { "name": "phasesenergized", "type": "esriFieldTypeSmallInteger", "alias": "Phases Energized", "domain": { "type": "codedValue", "name": "Electric_Distribution_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 0, "modelName": "phasesenergized" }, { "name": "phasessubstituted", "type": "esriFieldTypeInteger", "alias": "Phases Substituted", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "phasessubstituted" }, { "name": "phasefrequency", "type": "esriFieldTypeSmallInteger", "alias": "Phase Frequency", "domain": { "type": "codedValue", "name": "Electric_System_Frequency", "description": "Valid Frequencies for Phase", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 hz", "code": 50 }, { "name": "60 hz", "code": 60 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 60, "modelName": "phasefrequency" }, { "name": "numphasesconstructed", "type": "esriFieldTypeSmallInteger", "alias": "Num Phases Built", "domain": { "type": "codedValue", "name": "Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 3, "modelName": "numphasesconstructed" }, { "name": "grounding", "type": "esriFieldTypeSmallInteger", "alias": "Grounding", "domain": { "type": "codedValue", "name": "Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 3, "modelName": "grounding" }, { "name": "manufacturer", "type": "esriFieldTypeSmallInteger", "alias": "Manufacturer", "domain": { "type": "codedValue", "name": "Electric_Equipment_Manufacturer", "description": "All Electric Equipment Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "American Electric Lighting", "code": 2 }, { "name": "Beckwith Electric Company", "code": 3 }, { "name": "Canada Power Products", "code": 4 }, { "name": "Carte International", "code": 5 }, { "name": "Central Moloney Inc", "code": 6 }, { "name": "Challenger Electrical Equip CO", "code": 7 }, { "name": "Chardon Group", "code": 8 }, { "name": "Cooper Industries/Eaton", "code": 9 }, { "name": "Dowzer/Hevi Duty", "code": 10 }, { "name": "ERICO", "code": 11 }, { "name": "ERM Co", "code": 12 }, { "name": "ESCO Transformer Co", "code": 13 }, { "name": "Fargo Electric", "code": 14 }, { "name": "Farranti-Packard Transformer", "code": 15 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Glavan Electric", "code": 18 }, { "name": "Gordon Electric", "code": 19 }, { "name": "Gould Shawmut", "code": 20 }, { "name": "Howard Industries", "code": 21 }, { "name": "Hubbell", "code": 22 }, { "name": "Inertia Engineering & Machine Works", "code": 23 }, { "name": "ITT Bell and Gossett", "code": 24 }, { "name": "Jimelco", "code": 25 }, { "name": "Johnson Electric", "code": 26 }, { "name": "Kaiser", "code": 27 }, { "name": "Lindsey USA", "code": 28 }, { "name": "LittelFuse", "code": 29 }, { "name": "Magnetic Electric Co", "code": 30 }, { "name": "Meramac", "code": 31 }, { "name": "Mersen", "code": 32 }, { "name": "MGM Transformer Company", "code": 33 }, { "name": "Mid Central Electric", "code": 34 }, { "name": "Nova", "code": 35 }, { "name": "Pacific Air Switch Corp", "code": 36 }, { "name": "Pauwels", "code": 37 }, { "name": "Pennsylvania Transformer CO", "code": 38 }, { "name": "Philips", "code": 39 }, { "name": "Pole Star", "code": 40 }, { "name": "Power Delivery Products", "code": 41 }, { "name": "Power Partners", "code": 42 }, { "name": "Preformed Line Products", "code": 43 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "Sangamo", "code": 46 }, { "name": "Schneider Electric", "code": 47 }, { "name": "Schwager Wood", "code": 48 }, { "name": "Schweitzer", "code": 49 }, { "name": "Siemens", "code": 50 }, { "name": "Shallbetter", "code": 51 }, { "name": "Sola Hevi-Duty", "code": 52 }, { "name": "Sylvania", "code": 53 }, { "name": "T&R Electric", "code": 54 }, { "name": "TYCO", "code": 55 }, { "name": "Uptegraff", "code": 56 }, { "name": "Van Tran Transformers", "code": 57 }, { "name": "Other", "code": 9999 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "manufacturer" }, { "name": "nominalvoltage", "type": "esriFieldTypeInteger", "alias": "Primary Nominal Voltage (L-L)", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LL", "description": "Combined Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "253 V", "code": 253 }, { "name": "480 V", "code": 480 }, { "name": "528 V", "code": 528 }, { "name": "600 V", "code": 600 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 12470, "modelName": "nominalvoltage" }, { "name": "nominalvoltagelg", "type": "esriFieldTypeInteger", "alias": "Primary Nominal Voltage (L-G)", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LG", "description": "Combined Line to Ground Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 0, "modelName": "nominalvoltagelg" }, { "name": "maxvoltage", "type": "esriFieldTypeInteger", "alias": "Maximum Voltage", "domain": { "type": "codedValue", "name": "Electric_Combined_Maximum_Voltage", "description": "Combined Maximum Voltage Values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1.1 mV", "code": 1100000 }, { "name": "1.2 mV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 0, "modelName": "maxvoltage" }, { "name": "maxoperatingvoltage", "type": "esriFieldTypeInteger", "alias": "Maximum Operating Voltage", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LL", "description": "Combined Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "253 V", "code": 253 }, { "name": "480 V", "code": 480 }, { "name": "528 V", "code": 528 }, { "name": "600 V", "code": 600 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 0, "modelName": "maxoperatingvoltage" }, { "name": "compatibleunit", "type": "esriFieldTypeString", "alias": "Compatible Unit Code", "domain": null, "editable": true, "nullable": true, "length": 255, "defaultValue": null, "modelName": "compatibleunit" }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "Lifecycle_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Proposed and Approved", "code": 3 }, { "name": "Under Construction", "code": 4 }, { "name": "Approved and Under Construction", "code": 6 }, { "name": "Proposed, Approved and Under Construction", "code": 7 }, { "name": "In Service", "code": 8 }, { "name": "In Service and Under Construction", "code": 12 }, { "name": "In Service, Under Construction, and Approved", "code": 14 }, { "name": "In Service, Under Construction, Approved and Proposed", "code": 15 }, { "name": "To Be Retired", "code": 16 }, { "name": "In Service and To Be Retired", "code": 24 }, { "name": "Abandoned", "code": 32 }, { "name": "In Service, Proposed, and Abandoned", "code": 41 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": false, "defaultValue": 8, "modelName": "lifecyclestatus" }, { "name": "model", "type": "esriFieldTypeString", "alias": "Device Model", "domain": null, "editable": true, "nullable": true, "length": 255, "defaultValue": null, "modelName": "model" }, { "name": "loadtapchangermaximumchange", "type": "esriFieldTypeDouble", "alias": "Load Tap Changer Maximum Change", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "loadtapchangermaximumchange" }, { "name": "loadtapchangerlowerbandwidth", "type": "esriFieldTypeDouble", "alias": "Load Tap Changer Lower Bandwidth", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "loadtapchangerlowerbandwidth" }, { "name": "maximumboost", "type": "esriFieldTypeDouble", "alias": "Maximum Voltage Boost", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "maximumboost" }, { "name": "z0psimpedance", "type": "esriFieldTypeDouble", "alias": "Sequence Impedance -Z0ps", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "z0psimpedance" }, { "name": "z0xmimpedance", "type": "esriFieldTypeDouble", "alias": "Sequence Impedance -Z0xm", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "z0xmimpedance" }, { "name": "z1psimpedance", "type": "esriFieldTypeDouble", "alias": "Sequence Impedance -Z1ps", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "z1psimpedance" }, { "name": "x0r0impedance", "type": "esriFieldTypeDouble", "alias": "Sequence Impedance -X0/R0pm", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "x0r0impedance" }, { "name": "x1r1impedance", "type": "esriFieldTypeDouble", "alias": "Sequence Impedance -X1/R1", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "x1r1impedance" }, { "name": "z0pmimpedance", "type": "esriFieldTypeDouble", "alias": "Sequence Impedance -Z0pm", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "z0pmimpedance" }, { "name": "primarygroundimpedance", "type": "esriFieldTypeDouble", "alias": "Primary Ground Impedance (ohms)", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "primarygroundimpedance" }, { "name": "gridsidecouplinginductance", "type": "esriFieldTypeDouble", "alias": "Grid Side Coupling Inductance (ohms)", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "gridsidecouplinginductance" }, { "name": "remotecontrollerindicator", "type": "esriFieldTypeSmallInteger", "alias": "Remote Control Indicator", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "remotecontrollerindicator" }, { "name": "equipmentyype", "type": "esriFieldTypeSmallInteger", "alias": "Insulation Type", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "equipmentyype" }, { "name": "tapsandpoles", "type": "esriFieldTypeSmallInteger", "alias": "Number of Taps", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "tapsandpoles" }, { "name": "peakload", "type": "esriFieldTypeInteger", "alias": "Peak Load", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "peakload" }, { "name": "offpeakload", "type": "esriFieldTypeInteger", "alias": "Off Peak Load", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "offpeakload" }, { "name": "district", "type": "esriFieldTypeString", "alias": "District", "domain": null, "editable": true, "nullable": true, "length": 255, "defaultValue": null, "modelName": "district" }, { "name": "installdate", "type": "esriFieldTypeDate", "alias": "Install Date", "domain": null, "editable": true, "nullable": true, "length": 8, "defaultValue": null, "modelName": "installdate" }, { "name": "retireddate", "type": "esriFieldTypeDate", "alias": "Retired Date", "domain": null, "editable": true, "nullable": true, "length": 8, "defaultValue": null, "modelName": "retireddate" }, { "name": "inservicedate", "type": "esriFieldTypeDate", "alias": "In-Service Date", "domain": null, "editable": true, "nullable": true, "length": 8, "defaultValue": null, "modelName": "inservicedate" }, { "name": "isvalidloop", "type": "esriFieldTypeSmallInteger", "alias": "Is Valid Loop", "domain": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 0, "modelName": "isvalidloop" }, { "name": "spatialsource", "type": "esriFieldTypeSmallInteger", "alias": "Spatial Source", "domain": { "type": "codedValue", "name": "Spatial_Source", "description": "Source of the spatial location", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "As-Built", "code": 1 }, { "name": "CAD", "code": 2 }, { "name": "Digitized", "code": 3 }, { "name": "GPS/GNSS", "code": 4 }, { "name": "Field Sketch", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "spatialsource" }, { "name": "spatialconfidence", "type": "esriFieldTypeSmallInteger", "alias": "Spatial Confidence", "domain": { "type": "codedValue", "name": "Spatial_Confidence", "description": "Confidence in the accuracy of the spatial data", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High", "code": 1 }, { "name": "Medium", "code": 2 }, { "name": "Low", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "spatialconfidence" }, { "name": "ownedby", "type": "esriFieldTypeSmallInteger", "alias": "Owned by", "domain": { "type": "codedValue", "name": "Asset_Owner", "description": "The owner of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 1, "modelName": "ownedby" }, { "name": "maintby", "type": "esriFieldTypeSmallInteger", "alias": "Maintained By", "domain": { "type": "codedValue", "name": "Asset_Manager", "description": "The manager of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": 1, "modelName": "maintby" }, { "name": "notes", "type": "esriFieldTypeString", "alias": "General Notes", "domain": null, "editable": true, "nullable": true, "length": 2000, "defaultValue": null, "modelName": "notes" }, { "name": "symbolrotation", "type": "esriFieldTypeSmallInteger", "alias": "Symbol Rotation", "domain": { "type": "range", "name": "Symbol_Rotation", "description": "Valid range of degrees for rotation", "range": [ 0, 359 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "symbolrotation" }, { "name": "supportedsubnetworkname", "type": "esriFieldTypeString", "alias": "Supported subnetwork name", "domain": null, "editable": false, "nullable": false, "length": 2000, "defaultValue": "Unknown", "modelName": "supportedsubnetworkname" }, { "name": "supportingsubnetworkname", "type": "esriFieldTypeString", "alias": "Supporting subnetwork name", "domain": null, "editable": false, "nullable": false, "length": 2000, "defaultValue": "Unknown", "modelName": "supportingsubnetworkname" }, { "name": "devicestate", "type": "esriFieldTypeSmallInteger", "alias": "Device State", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "devicestate" }, { "name": "upperrange", "type": "esriFieldTypeDouble", "alias": "Upper Tempature Range - Operating", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "upperrange" }, { "name": "upperrangemetric", "type": "esriFieldTypeDouble", "alias": "Upper Tempature Range - Operating (Metric)", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "upperrangemetric" }, { "name": "lowerrange", "type": "esriFieldTypeDouble", "alias": "Lower Tempature Range - Operating", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "lowerrange" }, { "name": "lowerrangemetric", "type": "esriFieldTypeDouble", "alias": "Lower Tempature Range - Operating (Metric)", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "lowerrangemetric" }, { "name": "validationstatus", "type": "esriFieldTypeSmallInteger", "alias": "Validation status", "domain": { "type": "codedValue", "name": "Validation Status", "description": "The current record's validation status.", "codedValues": [ { "name": "No calculation required, no validation required, no error", "code": 0 }, { "name": "No calculation required, no validation required, has error(s)", "code": 1 }, { "name": "No calculation required, validation required, no error", "code": 2 }, { "name": "No calculation required, validation required, has error(s)", "code": 3 }, { "name": "Calculation required, no validation required, no error", "code": 4 }, { "name": "Calculation required, no validation required, has error(s)", "code": 5 }, { "name": "Calculation required, validation required, no error", "code": 6 }, { "name": "Calculation required, validation required, has error(s)", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "editable": false, "nullable": true, "defaultValue": 6, "modelName": "validationstatus" }, { "name": "primarygroundimpedance2", "type": "esriFieldTypeDouble", "alias": "Primary Ground Impedance Xg (ohms)", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "primarygroundimpedance2" }, { "name": "p2sphaseshift", "type": "esriFieldTypeSmallInteger", "alias": "Primary to Secondary Phase Shift", "domain": { "type": "range", "name": "Electric_Phase_Shift", "description": "Valid Phase Shift angles", "range": [ -30, 30 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "p2sphaseshift" }, { "name": "p2tphaseshift", "type": "esriFieldTypeSmallInteger", "alias": "Primary to Tertiary Phase Shift", "domain": { "type": "range", "name": "Electric_Phase_Shift", "description": "Valid Phase Shift angles", "range": [ -30, 30 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "p2tphaseshift" }, { "name": "secondaryvoltagelinetoline", "type": "esriFieldTypeInteger", "alias": "Secondary Voltage Line To Line", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LL", "description": "Combined Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "253 V", "code": 253 }, { "name": "480 V", "code": 480 }, { "name": "528 V", "code": 528 }, { "name": "600 V", "code": 600 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "secondaryvoltagelinetoline" }, { "name": "secondaryvoltagelinetoground", "type": "esriFieldTypeInteger", "alias": "Secondary Voltage Line To Ground", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LG", "description": "Combined Line to Ground Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "secondaryvoltagelinetoground" }, { "name": "tertiaryvoltagelinetoline", "type": "esriFieldTypeInteger", "alias": "Tertiary Voltage Line To Line", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LL", "description": "Combined Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "253 V", "code": 253 }, { "name": "480 V", "code": 480 }, { "name": "528 V", "code": 528 }, { "name": "600 V", "code": 600 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "tertiaryvoltagelinetoline" }, { "name": "tertiaryvoltagelinetoground", "type": "esriFieldTypeInteger", "alias": "Tertiary Voltage Line To Ground", "domain": { "type": "codedValue", "name": "Electric_Combined_Nominal_Voltage_LG", "description": "Combined Line to Ground Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "editable": true, "nullable": true, "defaultValue": null, "modelName": "tertiaryvoltagelinetoground" }, { "name": "maximumpower", "type": "esriFieldTypeInteger", "alias": "Maximum kVA", "domain": null, "editable": true, "nullable": true, "defaultValue": null, "modelName": "maximumpower" }, { "name": "GlobalID_1", "type": "esriFieldTypeGlobalID", "alias": "GlobalID_1", "domain": null, "editable": false, "nullable": false, "length": 38, "defaultValue": null, "modelName": "GlobalID_1" }, { "name": "FACILITYID", "type": "esriFieldTypeString", "alias": "Facility ID", "domain": null, "editable": true, "nullable": true, "length": 255, "defaultValue": null, "modelName": "FACILITYID" }, { "name": "GRIDID", "type": "esriFieldTypeString", "alias": "Grid ID", "domain": null, "editable": true, "nullable": true, "length": 255, "defaultValue": null, "modelName": "GRIDID" }, { "name": "IDNumber", "type": "esriFieldTypeString", "alias": "IDNumber", "domain": null, "editable": true, "nullable": true, "length": 6, "defaultValue": null, "modelName": "IDNumber" } ], "geometryField": { "name": "shape", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null, "editable": true, "nullable": false, "defaultValue": null, "modelName": "shape" }, "indexes": [ { "name": "I509globalid", "fields": "globalid", "isAscending": true, "isUnique": false, "description": "" }, { "name": "UUID_82", "fields": "GlobalID_1", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S7_idx", "fields": "shape", "isAscending": true, "isUnique": true, "description": "" } ], "datesInUnknownTimezone": false, "dateFieldsTimeReference": { "timeZone": "UTC", "respectsDaylightSaving": false }, "preferredTimeReference": null, "types": [ { "id": 0, "name": "Unknown", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Unknown", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 0, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 781, "name": "Grounding Transformer", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Grounding Transformer", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 781, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 782, "name": "Mobile Single Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Mobile Single Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 782, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 783, "name": "Mobile Three Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Mobile Three Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 783, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 784, "name": "Network", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Network", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 784, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 785, "name": "Overhead Single Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "__preset_OH Fused 1P Xfr_2", "description": "", "prototype": { "attributes": { "symbolrotation": 0, "assetgroup": 38, "phasescurrent": 7, "terminalconfiguration": "Default", "maxvoltage": 0, "nominalvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 0, "grounding": 0, "nominalvoltagelg": 0, "maxoperatingvoltage": 0, "isvalidloop": 0, "spatialsource": 0, "spatialconfidence": 0, "ownedby": 1, "maintby": 1, "phasessummer": 7, "assettype": 785, "lifecyclestatus": 8 } }, "drawingTool": "esriFeatureEditToolPoint" }, { "name": "Overhead Single Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 785, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 788, "name": "Overhead Three Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Overhead Three Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 788, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 789, "name": "Pad Mounted Single Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Pad Mounted Single Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 789, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 792, "name": "Pad Mounted Three Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Pad Mounted Three Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 792, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 793, "name": "Subsurface Single Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Subsurface Single Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 793, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 794, "name": "Subsurface Three Phase", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Subsurface Three Phase", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 794, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 795, "name": "Overhead Three Phase Open Delta", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Overhead Three Phase Open Delta", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 795, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 796, "name": "Overhead Three Phase Open Wye", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Overhead Three Phase Open Wye", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 796, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 797, "name": "Pad Mounted Three Phase Open Delta", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Pad Mounted Three Phase Open Delta", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 797, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] }, { "id": 798, "name": "Pad Mounted Three Phase Open Wye", "domains": { "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "subnetworkname": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": {"type": "inherited"}, "maxoperatingvoltage": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "issubnetworkcontroller": {"type": "inherited"}, "tiername": {"type": "inherited"}, "plandevicestatus": {"type": "inherited"}, "normaldevicestatus": {"type": "inherited"}, "currentdevicestatus": {"type": "inherited"}, "winterdevicestatus": {"type": "inherited"}, "summerdevicestatus": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"} }, "templates": [ { "name": "Pad Mounted Three Phase Open Wye", "description": "", "prototype": { "attributes": { "assetgroup": 38, "nominalvoltagelg": 0, "assettype": 798, "grounding": 3, "lifecyclestatus": 8, "nominalvoltage": 0, "ownedby": 1, "isvalidloop": 0, "maxoperatingvoltage": 0, "terminalconfiguration": "Default", "maintby": 1, "maxvoltage": 0, "subnetworkname": "Unknown", "phasesnormal": 7, "phasescurrent": 7, "phasessummer": 7, "phaseswinter": 7, "phasesplan": 7, "phasesenergized": 0, "numphasesconstructed": 3 } }, "drawingTool": "esriFeatureEditToolPoint" } ] } ], "templates": [], "subtypes": [ { "code": 0, "name": "Unknown", "defaultValues": { "assetgroup": 0, "assettype": null, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": null, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Network_5_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 1, "name": "Ground", "defaultValues": { "assetgroup": 1, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": null, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Ground", "description": "Ground", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bound", "code": 1 }, { "name": "Rod", "code": 2 }, { "name": "Voltage Grid", "code": 3 }, { "name": "Stray Voltage Isolator", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 2, "name": "High Voltage Arrester", "defaultValues": { "assetgroup": 2, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Arrester", "description": "High Voltage Arrester", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Indoor Arrester", "code": 21 }, { "name": "Line Arrester", "code": 22 }, { "name": "Station Arrester", "code": 23 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_High_Voltage_Discharge_Voltage", "description": "Maximum High Voltage discharge voltage", "range": [ 100000, 750000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Discharge_Current", "description": "High Voltage Discharge Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 kA", "code": 500 }, { "name": "1 kA", "code": 1000 }, { "name": "1.5 kA", "code": 1500 }, { "name": "2 kA", "code": 2000 }, { "name": "3 kA", "code": 3000 }, { "name": "5 kA", "code": 5000 }, { "name": "10 kA", "code": 10000 }, { "name": "15 kA", "code": 15000 }, { "name": "20 kA", "code": 20000 }, { "name": "40 kA", "code": 40000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 3, "name": "High Voltage Control Unit", "defaultValues": { "assetgroup": 3, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Control_Unit", "description": "High Voltage Controller", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Capacitor", "code": 41 }, { "name": "Switch and Breaker", "code": 42 }, { "name": "Voltage Regulator", "code": 43 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 4, "name": "High Voltage Generation", "defaultValues": { "assetgroup": 4, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Generation", "description": "High Voltage Generation", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Battery", "code": 61 }, { "name": "Biomass", "code": 62 }, { "name": "Coal", "code": 63 }, { "name": "Gas Turbine", "code": 64 }, { "name": "Geothermal", "code": 65 }, { "name": "Hydro", "code": 66 }, { "name": "Nuclear", "code": 67 }, { "name": "Photovoltaic Solar", "code": 68 }, { "name": "Thermal Solar", "code": 69 }, { "name": "Wind", "code": 70 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 5, "name": "High Voltage Line Monitor and Relay", "defaultValues": { "assetgroup": 5, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": 0, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay", "description": "High Voltage Line Monitor and Relay", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fault Indicator", "code": 80 }, { "name": "Instrument Transformer", "code": 81 }, { "name": "Load Monitor", "code": 82 }, { "name": "Relay", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Phase_Angle_Offset_Range", "description": "Phase Offset values 0 - 60", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 6, "name": "High Voltage Power Conversion", "defaultValues": { "assetgroup": 6, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Power_Conversion", "description": "High Voltage Power Conversion", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Inverter", "code": 101 }, { "name": "Rectifier", "code": 102 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_High_Voltage_DC_Voltage", "description": "Valid High Voltage Direct Current Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "270 kV", "code": 270000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "500 kV", "code": 500000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1000 kV", "code": 1000000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 }, { "name": "1400 kV", "code": 1400000 }, { "name": "1500 kV", "code": 1500000 }, { "name": "1800 kV", "code": 1800000 }, { "name": "2500 kV", "code": 2500000 }, { "name": "3000 kV", "code": 3000000 }, { "name": "4000 kV", "code": 4000000 }, { "name": "5000 kV", "code": 5000000 }, { "name": "6000 kV", "code": 6000000 }, { "name": "6400 kV", "code": 6400000 }, { "name": "7200 kV", "code": 7200000 }, { "name": "8000 kV", "code": 8000000 }, { "name": "10000 kV", "code": 10000000 }, { "name": "12000 kV", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 7, "name": "High Voltage Power Factor Correcting", "defaultValues": { "assetgroup": 7, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting", "description": "High Voltage Power Factor Correcting", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Capacitor", "code": 121 }, { "name": "AC Wave Trap", "code": 122 }, { "name": "AC Reactor", "code": 123 }, { "name": "DC Capacitor", "code": 124 }, { "name": "DC Reactor", "code": 125 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 8, "name": "High Voltage Regulator", "defaultValues": { "assetgroup": 8, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Regulator", "description": "High Voltage Regulator", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Single Phase", "code": 141 }, { "name": "AC Three Phase", "code": 142 }, { "name": "DC Regulator", "code": 143 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 9, "name": "High Voltage Service", "defaultValues": { "assetgroup": 9, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Service", "description": "High Voltage Service", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Metering", "code": 161 }, { "name": "DC Metering", "code": 162 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 10, "name": "High Voltage Switch", "defaultValues": { "assetgroup": 10, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Switch", "description": "High Voltage Switch", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Circuit Breaker", "code": 181 }, { "name": "AC Disconnect", "code": 182 }, { "name": "AC Switchgear", "code": 183 }, { "name": "DC Circuit Breaker", "code": 184 }, { "name": "DC Disconnect", "code": 185 }, { "name": "DC Switchgear", "code": 186 }, { "name": "AC Bus Tie Breaker", "code": 187 }, { "name": "DC Bus Tie Breaker", "code": 188 }, { "name": "AC Grounding", "code": 189 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 11, "name": "High Voltage Transformer", "defaultValues": { "assetgroup": 11, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 3, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_High_Voltage_Transformer", "description": "High Voltage Transformer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Single Phase Power", "code": 201 }, { "name": "AC Three Phase Power", "code": 202 }, { "name": "DC Power", "code": 203 }, { "name": "Grounding Transformer", "code": 204 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Transmission_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "Electric_Transmission_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_HighMedium_Nominal_Voltage_LL", "description": "High and Medium Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_HighMedium_Nominal_Voltage_LG", "description": "High and Medium Line to Ground Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_HighMedium_Nominal_Voltage_LL", "description": "High and Medium Line to Line Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "15 kV", "code": 15000 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 }, { "name": "115 kV", "code": 115000 }, { "name": "120 kV", "code": 120000 }, { "name": "138 kV", "code": 138000 }, { "name": "145 kV", "code": 145000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "362 kV", "code": 362000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_HighMedium_Nominal_Voltage_LG", "description": "High and Medium Line to Ground Nominal Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 mVA", "code": 5500000 }, { "name": "74 mVA", "code": 74000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 25, "name": "Medium Voltage Arrester", "defaultValues": { "assetgroup": 25, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Arrester", "description": "Medium Voltage Arrester", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Elbow Arrester", "code": 481 }, { "name": "Line Arrester", "code": 482 }, { "name": "Station Arrester", "code": 483 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Medium_Voltage_Discharge_Voltage", "description": "Maximum Medium Voltage discharge voltage", "range": [ 8000, 118000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Discharge_Current", "description": "High Voltage Discharge Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 kA", "code": 500 }, { "name": "1 kA", "code": 1000 }, { "name": "1.5 kA", "code": 1500 }, { "name": "2 kA", "code": 2000 }, { "name": "3 kA", "code": 3000 }, { "name": "5 kA", "code": 5000 }, { "name": "10 kA", "code": 10000 }, { "name": "15 kA", "code": 15000 }, { "name": "20 kA", "code": 20000 }, { "name": "40 kA", "code": 40000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 26, "name": "Medium Voltage Circuit Breaker", "defaultValues": { "assetgroup": 26, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker", "description": "Medium Voltage Circuit Breaker", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Network Protector", "code": 361 }, { "name": "Isolator Switch", "code": 501 }, { "name": "Single Phase Circuit Breaker", "code": 502 }, { "name": "Three Phase Circuit Breaker", "code": 503 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "65 Amps", "code": 65 }, { "name": "80 Amps", "code": 80 }, { "name": "100 Amps", "code": 100 }, { "name": "125 Amps", "code": 125 }, { "name": "150 Amps", "code": 150 }, { "name": "175 Amps", "code": 175 }, { "name": "180 Amps", "code": 180 }, { "name": "200 Amps", "code": 200 }, { "name": "225 Amps", "code": 225 }, { "name": "250 Amps", "code": 250 }, { "name": "300 Amps", "code": 300 }, { "name": "350 Amps", "code": 350 }, { "name": "400 Amps", "code": 400 }, { "name": "450 Amps", "code": 450 }, { "name": "500 Amps", "code": 500 }, { "name": "550 Amps", "code": 550 }, { "name": "600 Amps", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 27, "name": "Medium Voltage Control Unit", "defaultValues": { "assetgroup": 27, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Control_Unit", "description": "Medium Voltage Controller", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Capacitor", "code": 521 }, { "name": "Circuit Breaker", "code": 522 }, { "name": "Recloser", "code": 523 }, { "name": "Transfer Switch Controller", "code": 524 }, { "name": "Regulator", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 28, "name": "Medium Voltage Elbow", "defaultValues": { "assetgroup": 28, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Elbow", "description": "Medium Voltage Elbow", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Load Break Feedthru", "code": 541 }, { "name": "Load Break Junction", "code": 542 }, { "name": "Single Phase Dead Break", "code": 543 }, { "name": "Single Phase Load Break", "code": 544 }, { "name": "Three Phase Dead Break", "code": 545 }, { "name": "Three Phase Load Break", "code": 546 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "65 Amps", "code": 65 }, { "name": "80 Amps", "code": 80 }, { "name": "100 Amps", "code": 100 }, { "name": "125 Amps", "code": 125 }, { "name": "150 Amps", "code": 150 }, { "name": "175 Amps", "code": 175 }, { "name": "180 Amps", "code": 180 }, { "name": "200 Amps", "code": 200 }, { "name": "225 Amps", "code": 225 }, { "name": "250 Amps", "code": 250 }, { "name": "300 Amps", "code": 300 }, { "name": "350 Amps", "code": 350 }, { "name": "400 Amps", "code": 400 }, { "name": "450 Amps", "code": 450 }, { "name": "500 Amps", "code": 500 }, { "name": "550 Amps", "code": 550 }, { "name": "600 Amps", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 29, "name": "Medium Voltage Fuse", "defaultValues": { "assetgroup": 29, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Fuse", "description": "Medium Voltage Fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bayonet", "code": 561 }, { "name": "Fault Limiter", "code": 562 }, { "name": "Indoor Fuse", "code": 563 }, { "name": "Overhead Cutout Fused Disconnect", "code": 564 }, { "name": "Overhead Cutout Fused Load Break", "code": 565 }, { "name": "Overhead Cutout Sectionalizer", "code": 566 }, { "name": "Overhead Cutout Solid Blade", "code": 567 }, { "name": "Cabinet Fuse", "code": 568 }, { "name": "Underground Fuse", "code": 569 }, { "name": "Underground Fuse Disconnect", "code": 570 }, { "name": "Underground Fuse Load Break", "code": 571 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "65 Amps", "code": 65 }, { "name": "80 Amps", "code": 80 }, { "name": "100 Amps", "code": 100 }, { "name": "125 Amps", "code": 125 }, { "name": "150 Amps", "code": 150 }, { "name": "175 Amps", "code": 175 }, { "name": "180 Amps", "code": 180 }, { "name": "200 Amps", "code": 200 }, { "name": "225 Amps", "code": 225 }, { "name": "250 Amps", "code": 250 }, { "name": "300 Amps", "code": 300 }, { "name": "350 Amps", "code": 350 }, { "name": "400 Amps", "code": 400 }, { "name": "450 Amps", "code": 450 }, { "name": "500 Amps", "code": 500 }, { "name": "550 Amps", "code": 550 }, { "name": "600 Amps", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 30, "name": "Medium Voltage Generation", "defaultValues": { "assetgroup": 30, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Generation", "description": "Medium Voltage Generation", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Battery", "code": 61 }, { "name": "Biomass", "code": 62 }, { "name": "Gas Turbine", "code": 64 }, { "name": "Geothermal", "code": 65 }, { "name": "Hydro", "code": 66 }, { "name": "Photovoltaic Solar", "code": 68 }, { "name": "Thermal Solar", "code": 69 }, { "name": "Wind", "code": 70 }, { "name": "Generator", "code": 283 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 31, "name": "Medium Voltage Line Monitor and Relay", "defaultValues": { "assetgroup": 31, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay", "description": "Medium Voltage Line Monitor and Relay", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fault Indicator", "code": 601 }, { "name": "Instrument Transformer", "code": 602 }, { "name": "Programmable Logic Unit", "code": 603 }, { "name": "Remote Terminal Unit", "code": 604 }, { "name": "SCADA Load Monitor", "code": 605 }, { "name": "SCADA Weather Station", "code": 606 }, { "name": "Relay", "code": 607 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 32, "name": "Medium Voltage Motor and Pump", "defaultValues": { "assetgroup": 32, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump", "description": "Medium Voltage Motor & Pump", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase Motor", "code": 621 }, { "name": "Single Phase Pump", "code": 622 }, { "name": "Three Phase Motor", "code": 623 }, { "name": "Three Phase Pump", "code": 624 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 33, "name": "Medium Voltage Power Conversion", "defaultValues": { "assetgroup": 33, "assettype": null, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion", "description": "Medium Voltage Power Conversion", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Wave Trap", "code": 412 }, { "name": "Single Phase Inverter", "code": 641 }, { "name": "Single Phase Rectifier", "code": 642 }, { "name": "Three Phase Inverter", "code": 643 }, { "name": "Three Phase Rectifier", "code": 644 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 34, "name": "Medium Voltage Power Factor Correcting", "defaultValues": { "assetgroup": 34, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": null, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting", "description": "Medium Voltage Power Factor Correcting", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Mobile Harmonic Filter", "code": 401 }, { "name": "Mobile Reactor", "code": 402 }, { "name": "Pad Mounted Harmonic Filter", "code": 407 }, { "name": "Pad Mounted Reactor", "code": 408 }, { "name": "Station Capacitor", "code": 409 }, { "name": "Station Harmonic Filter", "code": 410 }, { "name": "Station Reactor", "code": 411 }, { "name": "Mobile Capacitor", "code": 661 }, { "name": "Overhead Single Phase Capacitor", "code": 664 }, { "name": "Overhead Three Phase Capacitor", "code": 665 }, { "name": "Overhead Harmonic Filter", "code": 666 }, { "name": "Overhead Reactor", "code": 667 }, { "name": "Pad Mounted Capacitor Single Phase", "code": 668 }, { "name": "Pad Mounted Capacitor Three Phase", "code": 669 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 35, "name": "Medium Voltage Regulator", "defaultValues": { "assetgroup": 35, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": null, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Regulator", "description": "Medium Voltage Regulator", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase VR", "code": 681 }, { "name": "Overhead Three Phase VR", "code": 683 }, { "name": "Pad Mounted Single Phase VR", "code": 685 }, { "name": "Pad Mounted Three Phase VR", "code": 687 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 36, "name": "Medium Voltage Service", "defaultValues": { "assetgroup": 36, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Service", "description": "Medium Voltage Service", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Primary Meter - Industrial Customer", "code": 701 }, { "name": "Primary Meter - Utility Customer", "code": 702 }, { "name": "Primary Meter Circuit Source", "code": 703 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 41, "name": "Medium Voltage Recloser", "defaultValues": { "assetgroup": 41, "assettype": null, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": null, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "grounding": 2, "manufacturer": null, "nominalvoltage": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Recloser", "description": "", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase Recloser", "code": 730 }, { "name": "Overhead Three Phase Recloser", "code": 744 }, { "name": "Pad Mounted Single Phase Recloser", "code": 747 }, { "name": "Pad Mounted Three Phase Recloser", "code": 748 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "65 Amps", "code": 65 }, { "name": "80 Amps", "code": 80 }, { "name": "100 Amps", "code": 100 }, { "name": "125 Amps", "code": 125 }, { "name": "150 Amps", "code": 150 }, { "name": "175 Amps", "code": 175 }, { "name": "180 Amps", "code": 180 }, { "name": "200 Amps", "code": 200 }, { "name": "225 Amps", "code": 225 }, { "name": "250 Amps", "code": 250 }, { "name": "300 Amps", "code": 300 }, { "name": "350 Amps", "code": 350 }, { "name": "400 Amps", "code": 400 }, { "name": "450 Amps", "code": 450 }, { "name": "500 Amps", "code": 500 }, { "name": "550 Amps", "code": 550 }, { "name": "600 Amps", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 42, "name": "Medium Voltage Sectionalizer", "defaultValues": { "assetgroup": 42, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": 0, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer", "description": "Medium Voltage Secitionalizer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase Sectionalizer", "code": 731 }, { "name": "Overhead Three Phase Sectionalizer", "code": 745 }, { "name": "Pad Mounted Single Phase Sectionalizer", "code": 749 }, { "name": "Pad Mounted Three Phase Sectionalizer", "code": 750 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "validationstatus": {"type": "inherited"} } }, { "code": 37, "name": "Medium Voltage Switch", "defaultValues": { "assetgroup": 37, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 2, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Switch", "description": "Medium Voltage Switch", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cabinet Bypass", "code": 721 }, { "name": "Cabinet Switch", "code": 722 }, { "name": "Cabinet Switch - Grounded", "code": 723 }, { "name": "Overhead Bypass", "code": 724 }, { "name": "Overhead Grounding Switch", "code": 725 }, { "name": "Overhead Jumper", "code": 726 }, { "name": "Overhead Single Phase Disconnect", "code": 728 }, { "name": "Overhead Single Phase Load Break", "code": 729 }, { "name": "Overhead Three Phase Disconnect", "code": 732 }, { "name": "Overhead Three Phase Load Break", "code": 733 }, { "name": "Pad Mounted Fault Interrupter", "code": 746 }, { "name": "Station Single Phase", "code": 751 }, { "name": "Station Three Phase", "code": 752 }, { "name": "T Blade", "code": 753 }, { "name": "V Blade", "code": 754 }, { "name": "Underground Single Phase Disconnect", "code": 755 }, { "name": "Underground Single Phase Load Break", "code": 758 }, { "name": "Underground Three Phase Disconnect", "code": 759 }, { "name": "Underground Three Phase Load Break", "code": 760 }, { "name": "Underground Transfer Switch", "code": 761 }, { "name": "Bus Tie Breaker", "code": 765 }, { "name": "Station Three Phase Disconnect", "code": 766 }, { "name": "Station Grounding", "code": 768 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "65 Amps", "code": 65 }, { "name": "80 Amps", "code": 80 }, { "name": "100 Amps", "code": 100 }, { "name": "125 Amps", "code": 125 }, { "name": "150 Amps", "code": 150 }, { "name": "175 Amps", "code": 175 }, { "name": "180 Amps", "code": 180 }, { "name": "200 Amps", "code": 200 }, { "name": "225 Amps", "code": 225 }, { "name": "250 Amps", "code": 250 }, { "name": "300 Amps", "code": 300 }, { "name": "350 Amps", "code": 350 }, { "name": "400 Amps", "code": 400 }, { "name": "450 Amps", "code": 450 }, { "name": "500 Amps", "code": 500 }, { "name": "550 Amps", "code": 550 }, { "name": "600 Amps", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 38, "name": "Medium Voltage Transformer", "defaultValues": { "assetgroup": 38, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": null, "manufacturer": null, "nominalvoltage": 0, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Transformer", "description": "Medium Voltage Transformer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounding Transformer", "code": 781 }, { "name": "Mobile Single Phase", "code": 782 }, { "name": "Mobile Three Phase", "code": 783 }, { "name": "Network", "code": 784 }, { "name": "Overhead Single Phase", "code": 785 }, { "name": "Overhead Three Phase", "code": 788 }, { "name": "Pad Mounted Single Phase", "code": 789 }, { "name": "Pad Mounted Three Phase", "code": 792 }, { "name": "Subsurface Single Phase", "code": 793 }, { "name": "Subsurface Three Phase", "code": 794 }, { "name": "Overhead Three Phase Open Delta", "code": 795 }, { "name": "Overhead Three Phase Open Wye", "code": 796 }, { "name": "Pad Mounted Three Phase Open Delta", "code": 797 }, { "name": "Pad Mounted Three Phase Open Wye", "code": 798 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 39, "name": "Medium Voltage Step Transformer", "defaultValues": { "assetgroup": 39, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": 0, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Medium_Voltage_Step_Transformer", "description": "List of Step Transformers used in Medium Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Step Down Single Phase", "code": 801 }, { "name": "Overhead Step Down Three Phase", "code": 802 }, { "name": "Overhead Step Up Single Phase", "code": 803 }, { "name": "Overhead Step Up Three Phase", "code": 804 }, { "name": "Pad Mounted Step Down Single Phase", "code": 805 }, { "name": "Pad Mounted Step Down Three Phase", "code": 806 }, { "name": "Pad Mounted Step Up Single Phase", "code": 807 }, { "name": "Pad Mounted Step Up Three Phase", "code": 808 }, { "name": "Submersible Step Down Single Phase", "code": 809 }, { "name": "Submersible Step Down Three Phase", "code": 810 }, { "name": "Submersible Step Up Single Phase", "code": 811 }, { "name": "Submersible Step Up Three Phase", "code": 812 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "20 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 40, "name": "Low Voltage Circuit Breaker", "defaultValues": { "assetgroup": 40, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 2, "manufacturer": null, "nominalvoltage": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": 0, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker", "description": "Asset Types for Low Voltage Circuit Breakers", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Circuit Breaker", "code": 471 }, { "name": "DC Circuit Breaker", "code": 472 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasescurrent": {"type": "inherited"}, "phasessummer": {"type": "inherited"}, "phaseswinter": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "100 Amps", "code": 100 }, { "name": "200 Amps", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 12, "name": "Low Voltage Arrester", "defaultValues": { "assetgroup": 12, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Arrester", "description": "Low Voltage Arrester", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Arrester", "code": 221 }, { "name": "Underground Arrester", "code": 222 }, { "name": "Station Arrester", "code": 223 }, { "name": "Indoor Arrester", "code": 224 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Discharge_Current", "description": "High Voltage Discharge Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 kA", "code": 500 }, { "name": "1 kA", "code": 1000 }, { "name": "1.5 kA", "code": 1500 }, { "name": "2 kA", "code": 2000 }, { "name": "3 kA", "code": 3000 }, { "name": "5 kA", "code": 5000 }, { "name": "10 kA", "code": 10000 }, { "name": "15 kA", "code": 15000 }, { "name": "20 kA", "code": 20000 }, { "name": "40 kA", "code": 40000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 13, "name": "Low Voltage Control Unit", "defaultValues": { "assetgroup": 13, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Control_Unit", "description": "Low Voltage Controller", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Control Unit", "code": 241 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 14, "name": "Low Voltage Fuse", "defaultValues": { "assetgroup": 14, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Fuse", "description": "Low Voltage Fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead", "code": 261 }, { "name": "AC Underground", "code": 262 }, { "name": "DC Overhead", "code": 263 }, { "name": "DC Underground", "code": 264 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "100 Amps", "code": 100 }, { "name": "200 Amps", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 15, "name": "Low Voltage Generation", "defaultValues": { "assetgroup": 15, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Generation", "description": "Low Voltage Generation", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Battery", "code": 61 }, { "name": "Car Charger", "code": 282 }, { "name": "Generator", "code": 283 }, { "name": "Residential Photovoltaic Solar", "code": 284 }, { "name": "Wind Turbine", "code": 285 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 16, "name": "Low Voltage Lighting", "defaultValues": { "assetgroup": 16, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Lighting", "description": "Low Voltage Lighting", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Flood light", "code": 301 }, { "name": "Streetlight", "code": 302 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 17, "name": "Low Voltage Line Monitor and Relay", "defaultValues": { "assetgroup": 17, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay", "description": "Low Voltage Line Monitor and Relay", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fault Indicator", "code": 321 }, { "name": "Load Monitor", "code": 322 }, { "name": "Relay", "code": 323 }, { "name": "Instrument Transformer", "code": 324 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 18, "name": "Low Voltage Motor", "defaultValues": { "assetgroup": 18, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Motor", "description": "Low Voltage Motor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase Motor", "code": 341 }, { "name": "Three Phase Motor", "code": 342 }, { "name": "DC Motor", "code": 343 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 19, "name": "Low Voltage Network Protection", "defaultValues": { "assetgroup": 19, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Network_Protection", "description": "Low Voltage Network Protection", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Network Protector", "code": 361 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "100 Amps", "code": 100 }, { "name": "200 Amps", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 20, "name": "Low Voltage Power Conversion", "defaultValues": { "assetgroup": 20, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 2, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Power_Conversion", "description": "Low Voltage Power Conversion", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase Inverter", "code": 381 }, { "name": "Single Phase Rectifier", "code": 382 }, { "name": "Three Phase Inverter", "code": 383 }, { "name": "Three Phase Rectifier", "code": 384 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 21, "name": "Low Voltage Power Factor Correcting", "defaultValues": { "assetgroup": 21, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting", "description": "Low Voltage Power Factor Correcting", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Mobile Harmonic Filter", "code": 401 }, { "name": "Mobile Reactor", "code": 402 }, { "name": "Overhead Capacitor", "code": 403 }, { "name": "Overhead Harmonic Filter", "code": 404 }, { "name": "Overhead Reactor", "code": 405 }, { "name": "Pad Mounted Capacitor", "code": 406 }, { "name": "Pad Mounted Harmonic Filter", "code": 407 }, { "name": "Pad Mounted Reactor", "code": 408 }, { "name": "Station Capacitor", "code": 409 }, { "name": "Station Harmonic Filter", "code": 410 }, { "name": "Station Reactor", "code": 411 }, { "name": "Wave Trap", "code": 412 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "upperrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrangemetric": { "type": "codedValue", "name": "Electric_Temperature_C", "description": "Temperature in Celsius", "codedValues": [ { "name": "0 C", "code": 0 }, { "name": "75 C", "code": 75 }, { "name": "90 C", "code": 90 }, { "name": "150 C", "code": 150 }, { "name": "190 C", "code": 190 }, { "name": "210 C", "code": 210 }, { "name": "230 C", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 22, "name": "Low Voltage Service", "defaultValues": { "assetgroup": 22, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Service", "description": "Low Voltage Service", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase Commercial", "code": 421 }, { "name": "Single Phase Residential", "code": 422 }, { "name": "Three Phase Commercial", "code": 423 }, { "name": "Three Phase Residential", "code": 424 }, { "name": "Unmetered Load", "code": 425 }, { "name": "DC Commercial", "code": 426 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 23, "name": "Low Voltage Switch", "defaultValues": { "assetgroup": 23, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": 0, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Switch", "description": "Low Voltage Switch", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead AC Load Break", "code": 441 }, { "name": "Overhead AC Disconnect", "code": 442 }, { "name": "Overhead DC Load Break", "code": 443 }, { "name": "Overhead DC Disconnect", "code": 444 }, { "name": "Underground AC Load Break", "code": 445 }, { "name": "Underground AC Disconnect", "code": 446 }, { "name": "Underground DC Load Break", "code": 447 }, { "name": "Underground DC Disconnect", "code": 448 }, { "name": "Indoor AC Load Break", "code": 449 }, { "name": "Indoor AC Disconnect", "code": 450 }, { "name": "Indoor DC Load Break", "code": 451 }, { "name": "Indoor DC Disconnect", "code": 452 }, { "name": "Source Selectable Switch", "code": 453 }, { "name": "Overhead Jumper", "code": 454 }, { "name": "AC Station", "code": 455 }, { "name": "DC Station", "code": 456 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 Amps", "code": 3 }, { "name": "7 Amps", "code": 7 }, { "name": "10 Amps", "code": 10 }, { "name": "15 Amps", "code": 15 }, { "name": "20 Amps", "code": 20 }, { "name": "25 Amps", "code": 25 }, { "name": "30 Amps", "code": 30 }, { "name": "40 Amps", "code": 40 }, { "name": "50 Amps", "code": 50 }, { "name": "100 Amps", "code": 100 }, { "name": "200 Amps", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } }, { "code": 24, "name": "Low Voltage Transformer", "defaultValues": { "assetgroup": 24, "assettype": 0, "associationstatus": 0, "isconnected": 2, "subnetworkcontrollername": "Unknown", "terminalconfiguration": "Default", "creationdate": null, "creator": null, "lastupdate": null, "updatedby": null, "globalid": null, "subnetworkname": "Unknown", "supportedsubnetworkname": "Unknown", "supportingsubnetworkname": "Unknown", "assetid": null, "phasesnormal": null, "phasescurrent": null, "phasessummer": null, "phaseswinter": null, "phasesplan": null, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": 0, "grounding": null, "manufacturer": null, "nominalvoltage": null, "maxvoltage": 0, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 8, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentyype": null, "tapsandpoles": null, "nominalvoltagelg": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "isvalidloop": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 1, "maintby": 1, "notes": null, "symbolrotation": null, "devicestate": null, "upperrange": null, "upperrangemetric": null, "lowerrange": null, "lowerrangemetric": null, "primarygroundimpedance2": null, "p2sphaseshift": null, "p2tphaseshift": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "maximumpower": null, "validationstatus": 6, "GlobalID_1": null, "FACILITYID": null, "GRIDID": null, "IDNumber": null }, "domains": { "assettype": { "type": "codedValue", "name": "Asset_Type_Electric_Device_Low_Voltage_Transformer", "description": "Low Voltage Transformer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 461 }, { "name": "Three Phase", "code": 462 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "associationstatus": {"type": "inherited"}, "isconnected": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasescurrent": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessummer": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phaseswinter": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "Electric_Secondary_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "Electric_Ground_Configuration_Transformer_Regulator", "description": "Grounding type for transformers and regulators", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "Approved", "code": 2 }, { "name": "Under Construction", "code": 4 }, { "name": "In Service", "code": 8 }, { "name": "To Be Retired", "code": 16 }, { "name": "Abandoned", "code": 32 }, { "name": "Retired", "code": 64 }, { "name": "Removed", "code": 128 }, { "name": "Out of Service", "code": 256 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentyype": { "type": "codedValue", "name": "Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "isvalidloop": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "devicestate": { "type": "codedValue", "name": "Electric_Device_State", "description": "Indicates if device is currently active on system", "codedValues": [ { "name": "Active", "code": 3 }, { "name": "Inactive", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance2": { "type": "range", "name": "Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoline": { "type": "codedValue", "name": "Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiaryvoltagelinetoground": { "type": "codedValue", "name": "Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "277 V", "code": 277 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "validationstatus": {"type": "inherited"} } } ], "maxRecordCount": 2000, "supportedQueryFormats": "JSON, geoJSON, PBF", "supportedExportFormats": "sqlite,filegdb", "capabilities": "Query,Create,Update,Delete,Uploads,Editing", "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "attachmentProperties": [ { "name": "id", "fieldName": "attachmentid", "isEnabled": true }, { "name": "globalId", "fieldName": "GLOBALID", "isEnabled": false }, { "name": "name", "fieldName": "att_name", "isEnabled": true }, { "name": "size", "fieldName": "data_size", "isEnabled": true }, { "name": "contentType", "fieldName": "content_type", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "attachmentid", "type": "esriFieldTypeOID", "alias": "attachmentid", "domain": null, "editable": false, "nullable": false, "defaultValue": null }, { "name": "att_name", "type": "esriFieldTypeString", "alias": "att_name", "domain": null, "editable": true, "nullable": false, "length": 250, "defaultValue": null }, { "name": "data_size", "type": "esriFieldTypeInteger", "alias": "data_size", "domain": null, "editable": true, "nullable": false, "defaultValue": null }, { "name": "content_type", "type": "esriFieldTypeString", "alias": "content_type", "domain": null, "editable": true, "nullable": false, "length": 150, "defaultValue": null } ], "standardMaxRecordCount": 32000, "tileMaxRecordCount": 8000, "standardMaxRecordCountNoGeometry": 32000, "maxRecordCountFactor": 1 }